background image

 
 

Page 

3

  of 

12

 

 

SAFETY INSTRUCTIONS

 

 
IMPORTANT! 

 

  Carefully read the instructions before operating the unit 

  This appliance is for indoor use only. Any outdoor use must be supervised and the 

unit must not be exposed to wet conditions such as rain. 

  Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. 

  Installation  must  be in accordance  with regulations of the country  where  the  unit  is 

used. 

  If you are in any doubt about the suitability of your electrical supply have it checked 

and, if necessary, modified by a qualified electrician. 

  This air cooler  has  been tested and  is safe to  use. However, as with any electrical 

appliance - use it with care.   

  Disconnect  the  power  from  the  appliance  before  changing  filters,  dismantling, 

assembling or cleaning. 

  Avoid touching any moving parts within the appliance. 

  Never insert fingers, pencils or any other objects though the guard   

  This appliance is  not intended for use by  persons  (including children)  with reduced 

physical, sensory or mental capabilities. It is also not intended for use by those with a 
lack  of  experience  and  knowledge,  unless  they  have  been  given  supervision  or 
instruction  concerning  the  use  of  the  appliance  by  a  person  responsible  for  their 
safety.   

  Do not leave children unsupervised with this appliance. 

  Do not clean the unit by spraying it or immersing it in water.   

  Never connect the unit to an electrical outlet using an extension cord. If an outlet is 

not available, one should be installed by a qualified electrician. 

  Never operate this appliance if the cord or plug is damaged. Ensure the power cord is 

not stretched or exposed to sharp objects / edges. 

  A  damaged  supply  cord  should  be  replaced  by  the  manufacturer  or  a  qualified 

electrician in order to avoid a hazard. 

  This appliance is designed for personal comfort and so should not be left unattended 

for extended periods. 

  Any service other than regular cleaning or filter replacement should be performed by 

an  authorised  service  representative.  Failure  to  comply  could  result  in  a  voided 
warranty. 

  Do not use the appliance for any purpose other than its intended use. 

  Never  use  the  plug  as  a  switch  to  start  and  turn  off  the  air  unit.  Use  the  provided 

ON/OFF switch located on the control panel. 

  Always place the unit on a dry and stable surface. Do not move or tilt the unit while 

the water tank is full. 

  The appliance should not be installed in laundry or wet rooms. 

  Do not use this unit in environments with flammable and explosive gases. 

  Avoid keeping the unit in direct sunlight for a long period of time. 

 

Summary of Contents for 1342935

Page 1: ...IVE COOLER Thank you for choosing electriQ Please read this user manual before using this innovative Air Cooler and keep it safe for future reference Visit our page www electriQ co uk for our entire r...

Page 2: ...NSTRUCTIONS 3 FEATURES 4 HOW EVAPORATIVE AIR COOLERS WORK 5 DIAGRAM 6 INSTALLATION 6 CONTROL PANEL 7 OPERATION 7 REMOTE CONTROL 9 FILLING THE WATER TANK 9 MAINTENANCE 10 TROUBLE SHOOTING 11 APPENDIX 1...

Page 3: ...e appliance by a person responsible for their safety Do not leave children unsupervised with this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an e...

Page 4: ...y in the room exceeds 60 The ambient operating temperature range is from 5 C to 40 C If used in low temperatures as a humidifier it is recommended to fill the water tank with warm but not hot water FE...

Page 5: ...ve humidity for optimum operation is 60 or lower A drier climate makes for more noticeable cooling The evaporative air cooler should not be used in enclosed or sealed spaces It must be kept level and...

Page 6: ...tical position Make sure all parts are present and the unit is assembled correctly WATER TANK Fill the water tank through the top water tank with water or ice ensuring the main water tank does not to...

Page 7: ...to indicate the mode currently selected Press to activate the swing mode The airflow will gently swing from left to right The vertical direction of the airflow can be adjusted manually The Swing symbo...

Page 8: ...minated when the ionizer is activated for enhanced air cleaning COOLING Illuminated when the cooling function is activated MODES NORMAL Fan operates at a constant level NATURAL The fan speed fluctuate...

Page 9: ...add water to the tank The appliance can be used without water in air cleaner mode Before filling with water open the cover on the top of the appliance and fill the water tank slowly before closing th...

Page 10: ...water has been standing in the tank for an extended period of time MAINTAINING AND CHANGING THE HONEYCOMB FILTER PADS The appliance is supplied with a set of honeycomb cooling filters pads The cleanin...

Page 11: ...comb cooling media will have an odour which will dissipate within a week of use 2 Honeycomb filter may have developed mould or bacterial growth 1 No action required 2 Clean the filter pads with mild a...

Page 12: ...to Friday www electriQ co uk Unit J6 Lowfields Way Elland West Yorkshire HX5 9DA Model Number ARCTIC60ER Description Symbol Value Unit Water Tank 60 Litres Voltage 220 240 V Frequency 50 Hz Power 280...

Reviews: