background image

 

OPTIONS FOR VENTING    

   

   
   
   

EXTERNAL VENTING   

If you have an outlet leading outside, your 
cooker hood can be connected as shown in 
the diagram using a flexible exhaust hose (not 
supplied). Any suitable extraction duct 
(enamel, aluminium, flexible pipe or other 
inflammable material with an interior diameter 
of 150mm) can be used. An adaptor is also 
supplied to enable you to connect your hood 
to pre-existing 120mm diameter ducting. 
Consideration of the route of the vent pipe 
should be made prior to installation. Please 
note: the performance of the hood may be 
affected if the diameter of the pipe is reduced, 
or if the airflow is restricted.    

   

   
   
   

   
       

RECIRCULATION    

The cooker hood also supports the recirculation 

of air, using filters to clean the air before 
expelling it through the vent holes in the side of 
the chimney. When installing the unit in this 
configuration, carbon filters should also be used 
to remove odours from the air. Details of 
sourcing and fitting the filters can be found in the 
Carbon Filter section of this manual.   

   

   

 

 

Summary of Contents for 1501085

Page 1: ...oker hood This instruction manual is designed to provide you with all required instructions related to the installation use and maintenance of the appliance In order to operate the unit correctly and...

Page 2: ...3 CONTENTS SAFETY 3 INSTALLATION 8 OPERATION 10 CLEANING AND MAINTENANCE 11 FILTER INFORMATION 12 LIGHT INFORMATION 13 TROUBSLEHSOOTING 14 SUPPORT 14 PRODUCT FICHE 15...

Page 3: ...not try to use the cooker hood without the grease filters or if the filters are excessively greasy They should be cleaned regularly see Maintenance or replaced as necessary The extraction fan must be...

Page 4: ...chieved by ensuring air is able to enter the room from outside through a suitable sized opening which cannot be sealed during operation A number of alternative solutions are available to ensure this I...

Page 5: ...6 V FLAP INSTALLATION DIMENSIONS...

Page 6: ...eter ducting Consideration of the route of the vent pipe should be made prior to installation Please note the performance of the hood may be affected if the diameter of the pipe is reduced or if the a...

Page 7: ...metal filter door remove the filter 2 Remove the stainless steel frame by removing the 4 x 4x10mm screws 3 Remove the lid of the terminal box and unplug the wires to the hood controls Then unplug the...

Page 8: ...rame back into place using the 4 screws removed as described in step 2 above 6 Reconnect the wires to the controls and lights 7 Replace the metal filter pressing in until it clicks into place 8 Instal...

Page 9: ...down mode or standby mode Increases motor speed When and are on Turns motor on When is off Automatic shutdown after 3 minutes When is on Turns motor off When is flashing Turns the motor and lights on...

Page 10: ...o be cleaned in a dishwasher using a 60 C program with the filter upright short sides upright in the lower basket Please be aware some dishwasher cleaning agents can permanently discolour the filter t...

Page 11: ...ON FILTER not supplied Activated carbon filters can be used to trap odours The activated carbon filter should be changed between three and six months according to use The installation procedure of act...

Page 12: ...bulbs hold with a cloth or gloves to ensure perspiration does not come in contact with the bulb as this can reduce the life of the bulb 1 Remove the grease filter 2 Put one hand into the cavity to ge...

Page 13: ...tance to between 65cm and 75cm INFORMATION FOR DISMANTLING Do not dismantle the appliance other than shown in the user manual The appliance cannot be dismantled by user At the end of life the applianc...

Page 14: ...low Qmax 394 2 m3 h Measured airflow rate at the best efficiency QBEP 227 1 m3 h Measured air pressure at best efficiency point PBEP 128 Pa Measured electric power input at best efficiency point WBEP...