background image

11 

 

EXHAUST  INSTALLATION  

The following rules must be strictly followed to obtain optimal air 

extraction: 

 Keep the expansion pipe short and straight. 

 Do not reduce the size or restrict expansion pipe. 

 When using an expansion pipe always install the pipe pulled 

taut to minimize pressure loss. 

 Failure to observe these basic instructions will reduce the 

performance and increase noise levels of the cooker hood. 

 Any installation work must be carried out by a qualified 

electrician or competent person. 

 Do not connect the ducting system of the hood to any existing 

ventilation system which is being used for any other appliance, 

such as a warmer tube, gas tube or hot wind tube. 

 The angle of the bend of the expansion pipe should be no less 

than 120º; you must direct the pipe horizontally, or, 

alternatively, the pipe should 

go up from the initial point 

and be led to an outer wall. 

 After the installation, make 

sure that the cooker hood is 

level to avoid grease 

collection at one end. 

 

NOTE:

 Ensure the expansion pipe selected for installation 

complies with relevant standards and is fire retardant.

 

 

 

 

Summary of Contents for eiQCURV60EN

Page 1: ...KER HOOD eiQCURV60 90EN eiQCURV60 90ENBL Please read this manual before using or installing the cooker hood and keep it safe for future reference Visit our page www electriQ co uk for our entire range...

Page 2: ...STALLATION OF FLAPS 6 EXTERNAL VENTILLATION 7 INSTALLATION 7 EXHAUST INSTALLATION 11 OPERATION 12 GREASE MESH FILTERS 12 CARBON FILTER 13 REPLACING THE BULB 14 CLEANING AND MAINTENANCE 15 TROUBLESHOOT...

Page 3: ...ouch the light bulb within 30 minutes of use Do not flamb or excessively flame under the hood Never leave frying food unattended as it can be a serious fire hazard If the supply cord is damaged it mus...

Page 4: ...hat is used for exhausting fumes from appliances burning gas or other fuels Regulations concerning the discharge of air have to be fulfilled The minimum distance between the supporting surface for the...

Page 5: ...TY Cooker Hood 1 Glass Canopy 1 Chimney Sections Pair 1 Outlet 1 Air Flap 2 Chimney bracket 1 Canopy Anti vibration ring 4 Canopy Mounting washer 4 Bolt M4 20 4 Screw ST4 40 2 Screw ST4 30 4 Wall plug...

Page 6: ...s at each end locate into the holes in the outlet vent When the unit is in operation the flaps pivot upwards to allow airflow Please note Ensure the small lugs at each end of each flap locate into the...

Page 7: ...llation method consideration to the route of the vent pipe should be made prior to installation NOTE the performance of the hood may be affected if the diameter of the pipe is reduced or if the airflo...

Page 8: ...re horizontal to prevent grease from accumulating within the hood Ensure the power has been turned off at the mains before starting installation Connection to the mains supply must be in an accessible...

Page 9: ...of the cooker hood measure the position of the holes inside and outside of the chimney bracket for hanging the hood 4 Drill 4 holes 2 for the inner chimney bracket and 2 for hanging the hood and keep...

Page 10: ...ach the adaptor 8 Hang the hood on the wall in the desired final position 9 Once the hood is positioned correctly fix the unit to the wall using 2 x ST4 30 screws and wall plugs through the fixing hol...

Page 11: ...ed out by a qualified electrician or competent person Do not connect the ducting system of the hood to any existing ventilation system which is being used for any other appliance such as a warmer tube...

Page 12: ...e do not apply unnecessary pressure Leave to dry naturally out of direct sun light Filters should be washed separately to crockery and kitchen utensils it is advisable not to use rinse aid Replacement...

Page 13: ...N ENBL eiQCF15290 for eiQCURV90EN ENBL The installation procedure is as below 1 Remove the grease filter 2 Unclip the wire from the reverse of the grease filter 3 Place the new carbon filter onto the...

Page 14: ...y reassembled ILCOS D code for this lamp is DBS 2 65 H 120 33 Max wattage 1 2 W Voltage range AC 110 240V NOTE The bulb must be replaced by the manufacturer its service agent or similarly qualified pe...

Page 15: ...th A specialized stainless steel cleaning fluid may be used 6 Ensure that wiping is done along with the grain of the stainless steel to prevent any unsightly crisscross scratching patterns from appear...

Page 16: ...nnections on the ventilation hose are tight Grease filters clogged Wash or replace the grease filters Excessive Vibration The fan blade is damaged Switch off the unit Repair to be carried out by quali...

Page 17: ...cial treatment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment t...