INSTALLATION  

 Unpack the hood and check that all functions are working. Ensure that 

the voltage (V) and the frequency (Hz) indicated on the serial plate 

match the voltage and frequency at the installation site.  

 Check that the area behind the installation surface is clear of any 

electrical cables or pipes, etc to avoid damage when drilling.  

 The surfaces of the hood can be very easily damaged during installation. 

Take care with tools to protect the surfaces during installation.  

 Protect the hob surface with cardboard, or similar, to prevent damage 

occurring whilst the hood is being installed above.  

 The manufacturer shall not be liable for any failure to observe all 

safety regulations in force for the correct and normal operation of 

electrical products. 

 Ensure the wall is level and the installation plates are horizontal to 

prevent grease from accumulating within the hood. 

 Ensure the power has been turned off at the mains before starting 

installation.  

 Connection to the mains supply must be in an accessible location.  

 You may need the following tools to complete this installation: 

  

 Drill appropriate for your wall  

 Phillips Screwdriver  

 Tape Measure  

 

 Electrical wiring must be done by a qualified professional in accordance 

with all applicable codes and standards, including fire rated construction.  

 

 IMPORTANT 

 Sufficient air is needed for proper combustion and exhaustion of gases 

through the flue (chimney) for fuel burning equipment to prevent back 

drafting. Ductless fans must always be vented to the outdoors.  

 When assessing the air pressure, the entire ventilation system in the 

house/apartment must be taken into account. 

 All legal regulations must be observed for the conveyance of exhaust air. 

If the extractor hood is used in recirculating mode with the optional 

carbon filter, there are no operating restrictions.    

 

 

Summary of Contents for eiQCURV60EN

Page 1: ...KER HOOD eiQCURV60 90EN eiQCURV60 90ENBL Please read this manual before using or installing the cooker hood and keep it safe for future reference Visit our page www electriQ co uk for our entire range...

Page 2: ...STALLATION OF FLAPS 6 EXTERNAL VENTILLATION 7 INSTALLATION 7 EXHAUST INSTALLATION 11 OPERATION 12 GREASE MESH FILTERS 12 CARBON FILTER 13 REPLACING THE BULB 14 CLEANING AND MAINTENANCE 15 TROUBLESHOOT...

Page 3: ...ouch the light bulb within 30 minutes of use Do not flamb or excessively flame under the hood Never leave frying food unattended as it can be a serious fire hazard If the supply cord is damaged it mus...

Page 4: ...hat is used for exhausting fumes from appliances burning gas or other fuels Regulations concerning the discharge of air have to be fulfilled The minimum distance between the supporting surface for the...

Page 5: ...TY Cooker Hood 1 Glass Canopy 1 Chimney Sections Pair 1 Outlet 1 Air Flap 2 Chimney bracket 1 Canopy Anti vibration ring 4 Canopy Mounting washer 4 Bolt M4 20 4 Screw ST4 40 2 Screw ST4 30 4 Wall plug...

Page 6: ...s at each end locate into the holes in the outlet vent When the unit is in operation the flaps pivot upwards to allow airflow Please note Ensure the small lugs at each end of each flap locate into the...

Page 7: ...llation method consideration to the route of the vent pipe should be made prior to installation NOTE the performance of the hood may be affected if the diameter of the pipe is reduced or if the airflo...

Page 8: ...re horizontal to prevent grease from accumulating within the hood Ensure the power has been turned off at the mains before starting installation Connection to the mains supply must be in an accessible...

Page 9: ...of the cooker hood measure the position of the holes inside and outside of the chimney bracket for hanging the hood 4 Drill 4 holes 2 for the inner chimney bracket and 2 for hanging the hood and keep...

Page 10: ...ach the adaptor 8 Hang the hood on the wall in the desired final position 9 Once the hood is positioned correctly fix the unit to the wall using 2 x ST4 30 screws and wall plugs through the fixing hol...

Page 11: ...ed out by a qualified electrician or competent person Do not connect the ducting system of the hood to any existing ventilation system which is being used for any other appliance such as a warmer tube...

Page 12: ...e do not apply unnecessary pressure Leave to dry naturally out of direct sun light Filters should be washed separately to crockery and kitchen utensils it is advisable not to use rinse aid Replacement...

Page 13: ...N ENBL eiQCF15290 for eiQCURV90EN ENBL The installation procedure is as below 1 Remove the grease filter 2 Unclip the wire from the reverse of the grease filter 3 Place the new carbon filter onto the...

Page 14: ...y reassembled ILCOS D code for this lamp is DBS 2 65 H 120 33 Max wattage 1 2 W Voltage range AC 110 240V NOTE The bulb must be replaced by the manufacturer its service agent or similarly qualified pe...

Page 15: ...th A specialized stainless steel cleaning fluid may be used 6 Ensure that wiping is done along with the grain of the stainless steel to prevent any unsightly crisscross scratching patterns from appear...

Page 16: ...nnections on the ventilation hose are tight Grease filters clogged Wash or replace the grease filters Excessive Vibration The fan blade is damaged Switch off the unit Repair to be carried out by quali...

Page 17: ...cial treatment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment t...

Page 18: ...18 PRODUCT FICHE eiQCURV60EN ENBL...

Page 19: ...19 eiQCURV90EN ENBL...