MAINTAINING AND CHANGING THE HONEYCOMB FILTER PADS
The appliance is supplied with a set of honeycomb cooling / filters pads. The cleaning frequency for the
honeycomb filters depend on local air and water conditions. In areas where the mineral content of the
water is high (hard water), mineral deposits may build up on the honeycomb filter and restrict air flow. If
mineral deposits remain on the honeycomb pads, the filter should be removed and washed under fresh
water. We recommend cleaning the honeycomb filter at least every two months, depending on your
needs.
For best results, allow the honeycomb filter to dry after each use by turning off the cooling function
for 15 minutes (with empty water tank) before turning the unit off.
Unplug the power cord, then unscrew the screws holding the filter frames in position. Remove the
filter frames from the appliance and take the honeycomb filter out of the frame. With a mild
detergent and a soft brush, scrub the honeycomb filter, clean with water and dry. Do not dip in water.
END OF SEASON MAINTENANCE
1. Empty the tank and wash it with warm soapy water.
2. Dry the tank and clean the Honeycomb pads
3. Store any Icepack you may use in the water tank
4. Cover the unit and keep it in a dry place.
Honeycomb
Filter
Filter Frame / Air Filter