Every unit displays the local actual values of voltage and power. There is no totals formation of the actual values of all
connected units. This can only be realised with the System Link Mode. See „8.3 System Link Mode“ for details.
Example configuration of a
serial connection
of three
80V
units (up to three 80V units in serial connection are allowed,
according to the safety provisions):
Using the power supply
Example configuration of a
serial connection
of two
300V
units. It is important, that the short connection between the
positive output of the one unit and the negative output of the other unit is grounded, either at the one or at the other unit!