ELECTRO FREEZE Shake Model CS705
184592
3
CAUTION
All materials and
connections must conform to
local requirements and be in
compliance with the National
Electric Code (NEC).
CAUTION
To prevent accidental
electrical shock, a receptacle
with a positive earth ground
is required.
1. Always verify electrical specifica-
tions on the data plate (figure 3-2) of each
individual freezer. Data plate specifica-
tions will always supersede the informa-
tion in this manual.
2. This freezer requires a protected
20 amp 230 volt circuit. Connect the
freezer to a circuit separate from any other
electrical equipment. The power cord on
this freezer connects to a NEMA 6-20R
receptacle. See Figure 2-1.
3. Supply voltage must be within
±10% of voltage indicated on the name-
plate. Request your local power company
to correct any voltage problem.
4. The control transformer in the
electrical box is factory wired to 208 volts
(red) wire tap for 208V nominal power
supply. If power supply is between 230-
240 volts use 240V (orange) wire tap on
transformer.
3.1
Particulars
3 Specifications
Figure 2-1
2.3 Electrical Connections
Width
(in/cm)
18.4/46.7
Height
(in/cm)
58.9/149.7
Depth
(in/cm)
28.1/71.4
Weight
(lbs/kg)
250/113.4
Voltage*
208-230/60/1
Min.Circuit Ampacit
y
20.0
Compressor
1 HP/8000 (BTUH)
.75 kw (Motor)
2.3 kw (Cooling)
Beater Motor
1/2 HP/.37 kw
Refrigerant
R-404a
Charge
32.0 oz/.91 kg
Cooling
Air
Hopper
20 qts/18.8 liters
Cylinder
7 qts/7.1 liters