ELECTRO FREEZE Shake Model CS700-FG
185231-17
32
13 Troubleshooting Charts
— continued
PROBLEM
PROBABLY CAUSE
REMEDY
Unit does not
operate.
1. Freezer unplugged.
1. Plug in freezer.
2. Fuse blown or breaker tripped at main
disconnect.
2.
Make sure your freezer is connected
to a separate circuit independent from
any other electrical equipment. Have
technician check fuse or breaker
size and check for low voltage; if not
within 10% of nameplate rating call
power company.
3. Actuator (plunger) rod not installed
3. Install actuator (plunger) rod.
4. Off on high pressure cut-out control.
4. Water turned off or defective water
regulating valve. Check water supply.
5. Circuit breaker tripped.
5. Contact your Electro Freeze
distributor for service.
6. Faulty selector switch
6. Contact your Electro Freeze
distributor for service.
7. Disconnected or broken wire in electrical
circuit.
7. Contact your Electro Freeze
distributor for service.
Mix or water
leaking from
drain tube to
drip tray.
1. Damaged beater shaft seal or installed
improperly.
1. Replace cup seals on washer. Install
properly.
Mix leaking
at dispensing
head.
1. Faulty o-ring.
1. Replace o-ring.
2.
Head not properly installed.
2. Install head properly. Replace o-ring
if pinched.
Dispensed
product too
soft. (Product
temperature
above 28°F
[-2.2°C])
1. Dirty or blocked condenser, restricted air
flow.
1. Unblock condenser or have cleaned
by your Electro Freeze distributor.
2.
Torque control not set firm enough.
2. Contact your Electro Freeze
distributor for service.
3. Component failure.
3. Contact your Electro Freeze
distributor for service.
4. Leak in refrigeration system resulting in
little or no refrigeration.
4. Contact your Electro Freeze
distributor for service.