ELECTRO FREEZE Soft Serve Model SL500
184599
15
6.2
Disassembly Instructions
CAUTION
To avoid electrical shock or contact with moving parts,
make sure all switches are in the “OFF” position and that
the main power supply is disconnected. Some freezers
have more than one disconnect switch.
It is important that the freezer be disassembled, washed, lubricated and sanitized
before operation. For maximum life on moving parts, disassemble and sanitize at
the end of every day of operation.
Figure 6-2
— continued
1. If there is product in the freezer,
refer to Section 9, Closing Procedures,
9.2 Draining Product.
2. Remove plunger rods (6, figure
6-2) by lifting up and swinging the
bottom out and down.
3. Remove the hand knobs (8) and
gently pull the dispensing head (1)
straight out.
4. Remove the beater shaft (1,
figure 6-3) from each cylinder. Then
remove breaker bar (1), scraper blades (3)
and shaft seal (3,4) from the beater shafts.
Remove the cup seals (4) from the washer
(5) on the shaft seal assembly.