24
184599
ELECTRO FREEZE Soft Serve Model SL500
8.2
Priming
Figure 8-3 Mix Feed Tube Installation
Priming the freezer removes all excess
sanitizer from the freezing cylinder, and
sets the proper overrun for the first cylinder
of product.
1.
Make sure that your hands,
forearms, and all freezer assemblies are
sanitized.
2.
Insert the mix feed tube assembly
into the hopper drain outlet.(figure 8-3)
Important:
Looking at the top of the mix feed tube
assembly the white dot on the white
plastic tube (regulator) must be in line
with the alignment mark on the metal
mix feed tube. This is the closed posi-
tion. (figure 8-4).
3.
Place a bucket under the dispense
head. (figure 8-5)
4.
Fill the mix hopper with mix.
5.
Open the plunger by pulling the
dispense handle down. Lift the white plastic
regulator in the mix feed tube, by turning
slightly. Hold the regulator up. When pure
mix is flowing from the dispense head
close the dispense handle. (figure 8-5)
Important:
Failure to completely remove sanitizer
or water from the freezing cylinder
before placing in “AUTO” will damage
the freezer.
Figure 8-5 Pure mix
Figure 8-4 Closed — position