37
ELECTRO FREEZE Soft Serve Model SL500
184599
12
Trouble Shooting Tables
(continued)
PROBLEM
PROBABLE CAUSE
REMEDY
Compressor
does not start
– hums
intermittently
(cycling on
overload).
1. Low line voltage.
1. Ask power company to check voltage,
increase voltage to not less than 10%
below data plate rating or install
transformer. Have electrician check for
inadequate wire size.
2. Improperly wired.
2. Contact your Electro Freeze distributor for
service.
3. Open start capacitor or current relay.
3. Contact your Electro Freeze distributor for
service.
4. High discharge pressure.
4. Contact your Electro Freeze distributor for
service.
1.
Dirty or blocked condenser, restricted
air flow – high ambient temperature.
1.
Have condenser cleaned by your Electro
Freeze distributor; lower ambient
temperature.
2.
Thermostat cut-in point out of
adjustment or malfunctioning.
2.
Contact your Electro Freeze distributor for
service.
3.
Defective condenser fan motor.
3.
Contact your Electro Freeze distributor for
service.
Poor or slow
product
recovery.
4.
Component or compressor failure.
4.
Contact your Electro Freeze distributor for
service.
1.
Head assembly is not installed.
1.
Install head assembly.
2.
Magnetic head switch defective.
2.
Contact your Electro Freeze Distributor
for service.
3.
Loose connection in control circuit.
3.
Contact your Electro Freeze Distributor
for service.
4.
Open starter coil.
4.
Contact your Electro Freeze Distributor
for service.
5.
Faulty capacitor assembly. (Single
phase only.)
5.
Contact your Electro Freeze Distributor
for service.
Beater motor
does not
operate.
6.
Faulty beater motor.
6.
Contact your Electro Freeze Distributor
for service.