EVOLUTION Pool Heater

Installation & Operating Manual

Summary of Contents for EVOLUTION

Page 1: ...EVOLUTION Pool Heater Installation Operating Manual ...

Page 2: ...l heater manufactured in England to the highest standards To ensure your new heater will give years of trouble free service please carefully read the following instructions Incorrect installation will affect your warranty Do not discard this manual please retain for future reference Product Overview Fig 1 ...

Page 3: ...hould be installed at a low point in the filtration system It should be positioned downstream after of the filter and upstream before of any dosing or other water treatment plant see fig 3 NOTE If the flow direction is reversed explained later in this booklet the heater must remain sited after the filter Factory set floor mount Foot position To reset for wall mount option undo the bolts and re ass...

Page 4: ...3 www elecro co uk ENGLISH Flow switch at top For vertical wall mounting water must always enter at the bottom Fig 3 Fig 4 ...

Page 5: ...f the heater is not used during winter months it must be drained to prevent frost damage Electrical Connection The heater must be installed in accordance with the country regional requirements regulations In any event the work must be carried out by a qualified electrician who will provide a certificate of conformity upon completion of the work The power supply must be fitted with a RCD If require...

Page 6: ...to ensure that it is finally locked in the correct orientation perpendicular at right angles to the flow of water ENGLISH Power Output Voltage V Amp 2 kW 230 9 3 kW 230 13 4 5 kW 230 20 6 kW 230 27 9 kW 230 40 12 kW 230 53 15 kW 230 66 18 kW 230 79 3 Phase Power Output 400 V Star 230 V Delta Amp 6 kW 400 230V 9 15 9 kW 400 230V 13 23 12 kW 400 230V 18 31 15 kW 400 230V 22 38 18 kW 400 230V 26 46 2...

Page 7: ...eel heaters are NOT suitable for use on saline salt water pools ONLY heaters with titanium heating elements are suitable for use on saline salt pools Water chemistry is complicated if in doubt seek expert advise Operating Instructions Upon completion of the installation run the water circulating pump to purge the system heater of air i e Remove any trapped air in the system heater TIP You can enco...

Page 8: ...ht On and then observe it again when the heater is in the standby mode ie amber light On The test should show that the meter is recording more electricity being used by the heater when the red light is On It is impossible for an electric heater to waste energy if it is drawing power then that power will be turned into heat that will be transferred to the water Accurate Function Test If a more accu...

Page 9: ...he water Trouble Shooting HEATER WILL NOT SWITCH FROM STANDBY AMBER LIGHT TO ON RED LIGHT In most cases this will be the result of one of the following points not being met Possible cause 1 The set point temperature has been achieved To confirm increase the set point value by turning the temperature set point dial to a value greater than the current water temperature Possible cause 2 The thermal s...

Page 10: ...ble Note the heater is not fitted with a fuse THE FLOW TUBE DOES NOT FEEL WARM Due to the high efficiency of your electric heater no warmth should be detectable from the flow tube of the heater The most likely causes of the flow tube feeling warm are Possible cause 1 The heater has been positioned in direct sunlight Possible cause 2 An air pocket is trapped inside the heater particularly if the ta...

Page 11: ...tes that this product should not be treated as household waste Instead it should be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this...

Page 12: ...ble in cases of incorrect installation of the heater inapropriate use or neglect of the heater CE Declaration Of Conformity The manufacturer declares that the herewith products or ranges ELECTRIC SWIMMING POOL HEATER RANGE Are in conformity with the provisions of the ELECTROMAGNETIC COMPATIBILITY directive 89 336 EEC as amended 93 068 EEC Controlled by AEMC Measures laboratory technical report no ...