Assemble Lateral Shift
1. Install the four threaded studs into the four T-slot nuts.
2. Insert two T-slot nut assemblies into each of the lateral shift extrusions (Figure 1).
3. Insert one self-tapping screw into each end of the extrusions to trap T-slot nut assemblies in the tracks (Figure 1).
4. Connect lateral shift extrusions to the plasma static wall mount by inserting the T-slot studs into holes and secure using four flat
washers, four lock washers, and four hex nuts (Figure 2).
Mount Lateral Shift
1. Locate and mark stud locations at desired mounting place.
2. Select four mounting holes in the lateral shift extrusions that will align with the stud pattern and mark at least two mounting
holes per extrusion at the stud locations.
WARNING: Your mounting structure must be capable of supporting four times the combined
weight of the plasma and the mount.
3. Mount the extrusions using a minimum of four anchors.
Mount Plasma
1. Using a 10-24 flat head cap screw inserted from chamfered hole side of each latching flag, install flags using Nylock nut
(see Figure 2). Tighten nut until the flag will hold itself in place using friction.
2. Place nylon mounting buttons on mounting holes and attach using M8-1.25 x 35 mm BHCS (See Figures 3 & 4).
3. Make sure the latches on the mount are lowered to the side before attempting to place the display on the mount.
4. With the aid of another person, lift the display up to the mount. Align the mounting buttons on the display with the
teardrop slots on the mount and set the display into place.
CAUTION
If the latches will not travel to the full upright position, remove and reseat the display.
5. While supporting the display, raise both latches to secure the display.
Figure 2
Figure 3
INSTALLATION INSTRUCTIONS
READ COMPLETELY BEFORE PROCEEDING
Figure 1
Figure 2
T-SLOT NUT ASSEMBLIES
SELF TAPPING
SCREW
SELF TAPPING
SCREW
Figure 4