Technical data
Weight, net
kg
188
Drum volume
litres
190
Drum diameter
mm
680
Drum depth
mm
555
Drum speed, medium load
rpm
47
Rated capacity, filling factor 1:18 (Max. load)
kg
10.6
Rated capacity, filling factor 1:22 (Max. recommended load)
kg
8.6
Sound power/pressure level at drying*
dB(A)
71/56
Average heat emission per drying cycle used to assess ventilation need**
kW
1.0
* Sound power levels measured according to ISO 60704.
** For assistance with dimensioning necessary ventilation needs, contact authorized ventilation technician. For suffi-
cient ventilation all sources introducing heat need to be taken into account plus all other parameters effecting the
ventilation need. Climate zone, building parameters, room size, etc.
Heat pump
Weight, net
kg
52
Pipe connection, condensed water
⌀
mm
19
Pipe connection, drain
⌀
mm
20
Water connection
3/4”
Type of refrigerant
R134a
Amount of refrigerant
kg
1.35
Fluorinated greenhouse gases
This product contains fluorinated greenhouse gases:
R134A: 1.350 kg
GWP 1430
CO
2
equivalent 1.931 t
Hermetically sealed