• Oil-affected items can ignite spontaneously, especially when exposed to heat sources

such as in a tumble dryer. The items become warm, causing an oxidation reaction in
the oil. Oxidation creates heat. If the heat cannot escape, the items can become hot
enough to catch fire. Piling, stacking or storing oil-affected items can prevent heat from
escaping and so create a fire hazard.

• If it is unavoidable that fabrics that contain vegetable or cooking oil or have been conta-

minated by hair care products be placed in a tumble dryer they should first be washed
in hot water with extra detergent – this will reduce, but not eliminate, the hazard.

• Maximum mass of dry cloth: 6 kg.
• A-weighted emission sound pressure level at working stations: 70 dB(A).

• Additional requirements for the following countries; AT, BE, BG, HR, CY, CZ, DK, EE,

FI, FR, DE, GR, HU, IS, IE, IT, LV, LT, LU, MT, NL, NO, PL, PT, RO, SK, SI, ES, SE, CH,
TR, UK:
– The appliance can be used in public areas.
– This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and knowl-
edge if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the ap-
pliance. Cleaning and user maintenance shall not be made by children without
supervision.

• Additional requirements for other countries:

– This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they
do not play with the appliance.

1.1

General safety information

In order to prevent damage to the electronics (and other parts) that may occur as the result of condensation, the ma-
chine should be placed in room temperature for 24 hours before being used for the first time.

1.2

Commercial use only

The machine/machines covered by this manual is/are made for commercial and industrial use only.

1.3

Symbols

Caution

Caution, hot surface

Caution, high voltage

Read the instructions before using the machine

Summary of Contents for QuickDry QDC N1130 Series

Page 1: ...User manual Tumble dryer TD6 6 LAB Type N1130 Original instructions 438921540 EN 2022 09 01 ...

Page 2: ......

Page 3: ...tional functions 12 5 4 When program has ended 13 6 Error codes 14 7 Maintenance 15 7 1 General 15 7 2 Time for maintenance 15 7 3 Every day 15 7 4 Fresh air intake 16 7 5 Check the air flow 17 7 6 Machines with residual moisture control RMC 17 7 7 Maintenance to be carried out by qualified service personnel 17 8 Disposal information 18 8 1 Disposal of appliance at end of life 18 8 2 Disposal of p...

Page 4: ......

Page 5: ...not be installed behind a lockable door a sliding door or a door with a hinge on the opposite side to that of the machine in such a way that a full opening of the machine is restricted If the machine has a lint trap this has to be cleaned frequently The lint must not be accumulated around the machine DO NOT MODIFY THIS APPLIANCE When performing service or replacing parts the power must be disconne...

Page 6: ... reduced physical sensory or mental capabilities or lack of experience and knowl edge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the ap pliance Cleaning and user maintenance shall not be made by children without supervision Additional requirements for other countries This applianc...

Page 7: ...nd or other that does not comply with the technical requirements for each appliance plumbing parts components or consumable cleaning products that are not approved by the manufacturer customer s negligence misuse abuse and or non compliance with the use and care instructions detailed within the appropriate equipment documentation improper or poor installation repair maintenance including tampering...

Page 8: ...8 User manual 3 Operating panel A B fig X01076 A Display B Control knob ...

Page 9: ...selected The program will stop when the time is up LOW LAB Program fulfills reguirements for ISO 6330 2012 Max exhaust temperature 60 C Different drying times can be selected The program will stop when the time is up NO HEATING Airing bedspreads duvets and bedclothes Different drying times can be selected The program will stop when the time is up Automatic programs Description NORMAL EXTRA DRY Den...

Page 10: ...al 5 Handling 5 1 Load Note Remove all objects from pockets and make sure there are no metal objects such as screws pins etc left Metal objects might cause damage to the drum Make sure the filter is clean fig 7363 ...

Page 11: ...kg 5 2 How to start the machine Time programs Select program by turning the control knob Example of programs NORMAL LAB LOW LAB NO HEATING Start the machine by pressing the control knob After start it is possible to change the time for the selected program Turn the control knob to set the desired time ...

Page 12: ...not be available or active on your machine Stop function If the machine is programmed with this function it is possible to stop the machine during program run by pressing the control knob When pressing the control knob again the program will continue Pause It is possible to pause an ongoing program Select PAUSE and activate For some machines it is also possible to pause directly when pressing the ...

Page 13: ...he machine Statistics Select STATISTICS and activate The statistics menu shows total run hours and trip run hours for the machine 5 4 When program has ended Note For the best possible drying result it is important to empty the machine as soon as the program has ended If the machine is not emptied as soon as the program has ended the drum will rotate in short intervalls in order to keep the goods f...

Page 14: ... machine is overfilled or the garment is too wet 12 12 DRYING ERROR WITH AUTOSTOP PROGRAM The longest permitted automatic stop time has been exceeded Applies only to machines with automatic stop The machine is overfilled or the garment is too wet 12 18 REDISTRIBUTION OF LOAD NEEDED Machine indicates that load is blocking the airflow Redistribute the load Restart the machine to clear error message ...

Page 15: ...le a telephone number and or a tag will also be displayed The machine can be used meanwhile However the message will keep coming back until the service is performed The message will disappear after about 30 seconds or if the control knob or any button is pressed 7 3 Every day Check that the machine does not operate with the door or filter door open if so the machine must be placed out of order unt...

Page 16: ...any lint and dust around the machine 7 4 Fresh air intake At regular basis check that the fresh air intake on the front of the machine is not clogged by lint and dust or otherwise blocked Clean with a vacuum cleaner fig 7386 ...

Page 17: ...trol Peak inlet temperature should reach 120 125 C Continue to monitor for 10 15 min and if needed readjust air flow Lock air damper setting after adjustment A 5 x A 1 m fig W00197B 7 6 Machines with residual moisture control RMC At regular basis wipe off clean drum and lifters with citric acid Acidum citricum If soap softener residue remains it is recommended also to use a coarse sponge Lack of c...

Page 18: ...ed and that the refrigerator and heat pump components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste but must be correctly disposed of in order to prevent any negative consequences for the environment and human health For further information on the recy cling of this product contact the local dealer or ag...

Page 19: ......

Page 20: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...