DOC
NUMBER
595R495
113
SERVICE MANUAL Blast Chiller Freezer 100 - 200
6.3.13 Evaporator
Steps for replacing the Evaporator:
ATTENTION!
Before replacing the evaporator, make sure that the suction valve and the exhaust gas valve are closed and then
follow the important procedures shown on page 103.
45. Perform the phase [
Opening the fan casings
] (page 107).
46. Remove the side protection (Figure 1 phase 1) and take out all the resistors (Figure 1 phase 2).
47. Disconnect all the fans, probes and resistors from the electric box (Figure 2 phase1).
48. Remove the fan casing (Figure 3 phase 1-2).
49. Desolder the connection pipes to the outdoor unit (Figure 4).