Installation manual
45
9.3
Gas installation
This gas appliance is build to run on natural gas (group I2H and I2E), commonly identified by GNH.
This default gas appliance is built to be installed at not over than 610 m (2001 ft) high altitude otherwise a kit for high
altitude must be installed to the machine. For the kit No. please refer to the spare parts list.
The data label shows the injector size and the injector pressure and the countries that use this gas quality:
AL
Albania
IE
Ireland
AT
Austria
IS
Iceland
BE
Belgium
IT
Italy
BG
Bulgaria
LT
Lithuania
CH
Switzerland
LU
Luxembourg
CY
Cyprus
LV
Latvia
CZ
Czech Republic
MK
Republic of Macedonia
DE
Germany
MT
Malta
DK
Denmark
NL
Netherlands
EE
Estonia
NO
Norway
ES
Spain
PL
Poland
FI
Finland
PT
Portugal
FR
France
RO
Romania
GB
United Kingdom
SE
Sweden
GR
Greece
SI
Slovenia
HR
Croatia
SK
Slovakia
HU
Hungary
TR
Turkey
You should check the kind of energy gas that is available in your place and check high altitude of the machine located
place.
There are many gas types of the same kind but the machine should be equipped with different kinds of nozzles de-
pending on the gas type.
9.4
Table of pressure and adjustment
Liquied petro-
leum gases
Gas category
Inlet pressure
(mbar)
Injector pres-
sure (mbar)
Injector size (
⌀
mm)
Air reducing
plate (mm)
Label number
May be avail-
able in follow-
ing countries
Butane mixture
/
Propane
mixture
3+
28-30 /
37
No regulation
2.30
No
490375643
BE, CH, CY,
CZ, ES, FR,
GB, GR, IE, IT,
LT, LU, LV, PT,
SK, SI
Butane
3B/P
30, 37, 50
28
2.30
No
490375644
BE, CY, DK,
EE, FI, FR, GB,
HU, IT, LT, NL,
NO, SE, SI, SK,
RO, HR, TR,
BG, IS, LU, MT,
PL, AT, CH, DE,
SK
Propane
3P
30, 37, 50
28
2.40
No
490375645
FI, NL, RO, BE,
CH, CZ, IE, IT,
ES, FR, GR,
GB, HR, LT, NL,
PL, PT, SI, SK,
AT, CH, DE,
NL, LU, SK
Summary of Contents for TD6-20
Page 2: ......
Page 59: ......
Page 60: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...