Installation manual
17
3.4.2
Technical data
Weight, net
kg
281
Drum volume
liters
360
Drum diameter
mm
755
Drum depth
mm
831
Drum speed, medium load
rpm
43
Rated capacity, filling factor 1:18 (Max. load)
kg
20
Rated capacity, filling factor 1:22 (Recommended load)
kg
16.4
Optimum air flow**
m
3
/h
N/A
Optimum static back pressure**
Pa
N/A
Maximum static back pressure**
Pa
N/A
Sound power/pressure level at drying*
dB(A)
72/56
Average heat emission per drying cycle used to assess ventilation need***
kW
1.5
Ambient operating temperature
℃
+10 – +45
* Sound power levels measured according to ISO 60704.
** In a cold empty machine.
*** For assistance with dimensioning necessary ventilation needs, contact authorized ventilation technician. For suffi-
cient ventilation all sources introducing heat need to be taken into account plus all other parameters effecting the
ventilation need. Climate zone, building parameters, room size, etc.
Connections
Pipe connection, condensed water
⌀
mm
15
Heat pump
Type of refrigerant
R134a
Amount of refrigerant
kg
1.6
Fluorinated greenhouse gases
This product contains fluorinated greenhouse gases:
R134a: 1.600 kg
GWP 1430
CO
2
equivalent 2.288 t
Hermetically sealed