background image

Installation manual

11

4.2

Recycling instruction for packaging

4

5

6

7

3

1

2

fig.X02403

Fig.

Description

Code

Type

1

Wrapping film

LDPE 4

Plastics

2

Corner protection

PS 6

Plastics

3

Cardboard packaging

PAP 20

Paper

4

Pallet

FOR 50

Wood

5

Screw

FE 40

Steel

6

Steel Bracket

FE 40

Steel

7

Plastic bag

PET 1

Plastics

Summary of Contents for TD6-6 LAB

Page 1: ...Installation manual Tumble dryer TD6 6 LAB Type N1130 Original instructions 438917600 EN 2022 09 01 ...

Page 2: ......

Page 3: ... 5 2 Fresh air 13 5 3 Calibration of air damper 14 5 4 Exhaust duct 15 5 5 Shared exhaust duct 16 5 6 Exhaust dimensioning 16 6 Electrical connection 17 6 1 Electrical installation 17 6 2 Single phase connection 17 6 3 Three phase connection 18 6 4 Electrical connections 19 7 Reversing the door 20 8 At first power up 22 8 1 Select language 22 8 2 Set time and date 22 9 Function check 23 10 Disposa...

Page 4: ......

Page 5: ...ust not be installed behind a lockable door a sliding door or a door with a hinge on the opposite side to that of the machine in such a way that a full opening of the machine is restricted If the machine has a lint trap this has to be cleaned frequently The lint must not be accumulated around the machine DO NOT MODIFY THIS APPLIANCE When performing service or replacing parts the power must be disc...

Page 6: ...with reduced physical sensory or mental capabilities or lack of experience and knowl edge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the ap pliance Cleaning and user maintenance shall not be made by children without supervision Additional requirements for other countries This appl...

Page 7: ...es and or other that does not comply with the technical requirements for each appliance plumbing parts components or consumable cleaning products that are not approved by the manufacturer customer s negligence misuse abuse and or non compliance with the use and care instructions detailed within the appropriate equipment documentation improper or poor installation repair maintenance including tampe...

Page 8: ...allation manual 3 Technical data 3 1 Drawing C 2 3 4 F G E D A 1 B fig X02281 1 Operating panel 2 Door opening 370 mm 3 Electrical connection 4 Exhaust connection A B C D E mm 595 715 840 140 50 F G mm 90 200 ...

Page 9: ...meter mm 575 Drum depth mm 500 Drum speed rpm 53 G factor max 0 9 Rated capacity filling factor 1 22 Max load kg 6 Heating Electricity kW 5 1 kW 3 2 A weighted emission sound pressure level at working stations dB A 70 Heat emission of installed power max 15 3 3 Connections Air outlet mm 100 ...

Page 10: ...10 Installation manual 4 Setup 4 1 Unpacking Remove the machine from the pallet Note When moving the machine handle it with care The drum has no transport clamps Place the machine on its final position ...

Page 11: ...ckaging 4 5 6 7 3 1 2 fig X02403 Fig Description Code Type 1 Wrapping film LDPE 4 Plastics 2 Corner protection PS 6 Plastics 3 Cardboard packaging PAP 20 Paper 4 Pallet FOR 50 Wood 5 Screw FE 40 Steel 6 Steel Bracket FE 40 Steel 7 Plastic bag PET 1 Plastics ...

Page 12: ...g both for the user and service personnel Respecting the given recommendations will provide easy access for maintenance and service operations In case of space limitations it is possible to install machines without respecting to the given recommendations If so keep in mind that it might be necessary to disconnect and move other machines to be able to reach and perform service on affected machine 4...

Page 13: ...rtest possible drying time it is important to ensure that fresh air is able to enter the room from the outside in the same volume as that is blown out of the room To avoid draught in the room it is important to place the air inlet behind the machine The area of the air inlet opening is recommended to be five times the size of the exhaust pipe area The area of the inlet opening is the area through ...

Page 14: ... Check maximum inlet temperature with the following procedure Start a NORMAL LAB program without load Activate the STATUS menu and monitor inlet temperature Start adjustment procedure with fully open damper After approximate 10 min heating adjust damper to peak inlet temperature of 120 125 C To increase temperature close damper to decrease temperature open damper Note that the inlet temperature va...

Page 15: ...at extend into the duct and catch lint The exhaust air should not be vented into a wall a ceiling or a concealed space of building The exhaust duct must lead clear of the building as condensation may cause frost damage to the building The exhaust duct must lead to the outdoors The exhaust duct must be placed in such a way that it is protected on the outside The exhaust duct must be smooth on the i...

Page 16: ...140 280 420 560 mm 100 100 100 100 Fresh air inlet cm2 300 400 600 800 Exhaust duct length 0 6 m mm 100 100 160 160 Exhaust duct length 6 50 m mm If the exhaust duct length exceeds 6 m the diameter must be increased 100 160 200 200 The exhaust duct diameter must not be reduced 5 6 Exhaust dimensioning It is important that the machine has correct air volume compared to each machines power If the ai...

Page 17: ... it is important that the earth wire is properly connected In instances where the machine is not equipped with an omni polar switch one must be installed beforehand In accordance with the wiring rules mount a multi pole switch prior to the machine to facilitate installation and service operations The connecting cable shall hang in a gentle curve 6 2 Single phase connection Demount the cover panel ...

Page 18: ... L1 PE L2 L3 380 440V 3 5 1kW bn BK GY bu BN L2 L3 L1 BK BN GY X1 L1 L2 L3 N PE E2 1 6kW E1 1 6kW 1 2 E3 1 9kW 1 2 1 2 4 5 4 5 4 5 L1 PE L2 L3 440V 3 2 6kW bn BK GY bu BN BK BN GY L2 L3 L1 X1 L1 L2 L3 N PE E2 1 6kW E1 1 6kW 1 2 E3 1 9kW 1 2 1 2 4 5 4 5 4 5 L1 PE L2 L3 380 415V 3N 5 1kW bn BK GY bu BN BK BN GY L2 L3 L1 X1 L1 L2 L3 N PE E2 1 6kW E1 1 6kW 1 2 E3 1 9kW 1 2 1 2 4 5 4 5 4 5 N L1 PE L2 L...

Page 19: ...Installation manual 19 6 4 Electrical connections Heating alternative Main voltage Hz Heating power kW Total power kW Recommended fuse A Electric heating 220V 1 50 60 2 9 3 2 16 400V 3 50 60 3 2 3 5 10 ...

Page 20: ...he cover screws on the other side and mount them where the hinges was Mount the hinges on the other side where the cover screws was Mount the lower hinge soft with one screw first in order to make it easier to place the door back in position fig W00182A Demount the door handle and remount the screws Mount the door handle on the opposite side using the existing screws Remove the upper and lower piv...

Page 21: ...them over and press into position fig W00184A Mount the door on the other side Push the door and the top pivot into the upper hinge and then adjust the lower pivot into the lower hinge Mount the remaining screw when the lower pivot is in correct position Tighten the screws Connect the power to the machine Test run the machine ...

Page 22: ...Select language from the list on the display This will be the language that all display messages program names etc will be presented in 8 2 Set time and date Select YES and press the control knob to get to the menu TIME DATE Activate the SET TIME menu and set the correct time Save the settings Activate the SET DATE menu and set the correct date Start by setting the year Set the year Exit to contin...

Page 23: ...k the automatic stop of the machine Start the machine Check if the micro switches are working properly The machine must stop if the door is opened Check the heat Let the machine work for five minutes on a program with heat Check that the heating is working by opening the door and feel if there is heat in the drum Ready to use If all tests are OK the machine is now ready to be used If some of the t...

Page 24: ...cycled and that the refrigerator and heat pump components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste but must be correctly disposed of in order to prevent any negative consequences for the environment and human health For further information on the recy cling of this product contact the local dealer o...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...

Reviews: