Connect the hose from the compressed air supply to the bushing on the pressure regulator.
Connect the hose so it hangs in a gentle arc. (This is particularly important if the machine is fitted with a tilting
function).
The connecting hose must be rated for a pressure of at least 1 MPa.
G
fig.5871A
8 Drain connection
The connector for the machine discharge (A) has an external diameter of 110 mm. The distance between the ma-
chine and the floor gully or drainage channel should be at least 250 mm.
Connect a hose or a pipe to the drain connection. Avoid sharp bends which may prevent proper draining. The hose
or pipe should open into a floor gully, drainage channel or similar waste outlet. Make sure that the hose’s function is
unaffected if the machine is fitted with a tilting function.
If the machine has a second discharge, B and C must also be connected to the floor drain.
250 mm /
9 13/16 inch
B
A
C
fig.5577A