30
Installation manual
12.1 Electrical connections
W4400H
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
220-240V 3 ~
50/60
36.0
38.0
100
380-415V 3 ~
50/60
32.8
34.8
63
440/480V 3 ~
50/60
36.0
38.0
63/50
220V 3 ~
50/60
32.9
35.0
100
200V 3 ~
50/60
27.2
85.6
100
400V 3 ~
50
36.0
38.0
63
Non heated/Steam
heated
220-240V 3 ~
50/60
-
4.5
20
380-480V 3 ~
50/60
-
4.5
10
200V 3 ~
50/60
-
4.5
16
400V 3 ~
50
-
4.5
10
W4600H
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
220-240V 3 ~
50/60
38.4/54.0
41.0/56.6
125/160
380-415V 3 ~
50/60
38.4/54.0
41.0/56.6
63/100
440/480V 3 ~
50/60
38.4/54.0
41.0/56.6
63/80
220V 3 ~
50/60
49.4
52.0
160
200V 3 ~
50/60
29.0/40.8
31.6/43.4
100/160
400V 3 ~
50
38.4/54.0
41.0/56.6
63/100
Non heated/Steam
heated
220-240V 3 ~
50/60
-
4.8
20
380-480V 3 ~
50/60
-
4.8
16
200V 3 ~
50/60
-
4.5
20
400V 3 ~
50
-
4.5
10
W4850H
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Non heated/Steam
heated
220-240V 3 ~
50/60
-
6.3
25
380-480V 3 ~
50/60
-
6.3
16
200V 3 ~
50/60
-
6.3
35
400V 3 ~
50
-
6.3
16
W41100H
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Non heated/Steam
heated
220-240V 3 ~
50/60
-
6.3
25
380-480V 3 ~
50/60
-
6.3
16
200V 3 ~
50/60
-
6.3
35
400V 3 ~
50
-
6.3
16
Summary of Contents for W4 H Series
Page 2: ......
Page 4: ......
Page 39: ......
Page 40: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...