Installation manual
33
For machines with tilt both forwards and backwards
Fit two pneumatic position sensors (C) on two of the machine feet: at left-hand front and right-hand rear, diagonally
opposed. The position sensors are to be fitted using the inner two fastening bolts of the feet, mounted on the corner
posts just installed.
C
fig.6046A
The compressed air lines which are to be connected to the air bellows and position sensors are supplied bundled on
the machine rear.
Connect the lines to the air bellows and pressure sensors according to the table below. These lines do not need to
be fastened to the frame, but can be laid on the floor underneath the machine.
The air lines are marked as follows:
ID marking
Connect to
1
Rear air bellows
2
Front air bellows
3
Rear pressure sensor, connection 1
4
Rear pressure sensor, connection 2
5
Front pressure sensor, connection 1
6
Front pressure sensor, connection 2
2
1
6
5
3
4
fig.6047A
Summary of Contents for W4 H Series
Page 2: ......
Page 4: ......
Page 39: ......
Page 40: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...