38
Installation manual
10 Barrier partition
Leave at least 1 m (40") (according to the recommendation in standard EN 60204) between the machine, a wall or
any other machine at the sides.
mm/in
A
B
C
D
WPB4 700H
1570
2080
2040
1490
WPB4 900H
1800
2080
2040
1720
WPB4 1100H
2030
2080
2040
1950
* Minimum 70 mm (2.76″),, maximum 100 mm (4″),.
• The barrier partition (O) shall be built before the installation of the machine.
• Centre and align the washer-extractor with the frame (P) 60x100mm (2x4”) maximum (provided by customer)..
• Place the rubber seal (R) inside the aluminium extruded section (S).
• Screw the aluminium extruded section (S) on the frame or on the optional plates (P).
If machines are to be installed in an existing wall thicker than 100 mm (4″), we recommend you order our special
aseptic frame kit.