52
Installation manual
Steam connection low pressure
Hereunder values apply to the steam pressure:
Recommended pressure: 250 kPa (0.5 kg/cm²) (36 psi)
Connection size: DN 32 (1"1/4 BSP male).
Connect the steam installation on the top of the machine (see example sketch).
A
Washer-extractor
S
Steam inlet
Y
Manual stop wheel valve DN 32 (1"1/4 BSP) (provided by customer)
P
Steam filter DN 32 (1"1/4 BSP) (provided)
F
Steam special flexible pipe DN 32 (1"1/4 BSP) (provided) length : 70 cm
U
Pipe union DN 32 male/female (1"1/4 BSP) (provided)
17 Air vent connection
The air vent of the outer drum opens on the top of the machine. Connect the bent hose to this opening.
Connect the air vent, to the outside of the laundry in accordance with the legislation.
The air vent should resist to 100 °C (212 °F) temperature and allow the condenses to return to the machine.