When the motor reaches approximately 80 percent of its normal run speed, the start winding centrifugal switch
opens removing power from the start winding. The run winding centrifugal switch changes from motor terminal
M6 to motor terminal M8. M8 is connected to terminal T8L of the timer. During agitation, T8L is closed to
terminal T9L of the timer that supplies power to Terminal 1 of the speed switch. If the speed switch is set to
Normal,
terminal 1 of the speed switch is connected to terminal 5 of the speed switch that supplies power to
terminal T4 of the timer. Terminal T4 of the timer is connected to terminal M6 that supplies power to the high
speed run winding. If the speed switch is set to
Gentle,
terminal 1 of the speed switch is connected to terminal
4 of the speed switch that supply power to terminal M11 of the motor. Terminal M11 supplies power to the low
speed run winding. If the speed switch is set to
Extra Gentle,
terminal 1 of the speed switch is connected to
terminal 3 of the speed switch that supplies power to terminal M10 of the motor. Terminal M10 supplies power
to the extra low speed run winding.
Note:
The drive motor always starts at high speed, then changes to the speed switch setting.
Agitation cycle - motor running