When the motor reaches approximately 80 percent of its normal run speed the start winding centrifugal switch
opens, removing power from the start winding. The run winding centrifugal switch changes from motor terminal
M6 to motor terminal M8. M8 is connected to terminal T8L of the timer. During spin, T8L is closed to terminal
T12 of the timer that supplies power to terminal 2 of the speed switch. If the speed switch is set to
Normal/Fast
or
Gentle/Fast,
terminal 2 of the speed switch is connected to terminal 5 of the speed switch that supplies
power to terminal T4 of the timer. Terminal T4 of the timer is connected to terminal M6 of the motor that
supplies power to the high speed run winding. If the speed switch is set to
Gentle/Slow
or
Extra Gentle/ Slow,
terminal 2 of the speed switch is connected to terminal 4 of the speed switch that supplies power to terminal M11
of the motor. Terminal M11 supplies power to the low speed run winding.
Spin cycle - motor running