38
TROUBLESHOOTING
Igniter does not spark when any of the switches
are turned to the lite position:
1. Check electrical power to range.
2. Turn the gas off to the range. Remove the back cover
and with the switches turn to lite position measure
the input voltage to the sparkmodule. If the meter
reads zero the wire to the switches or from the
switches is broken. If the meter reads 120 VAC go
to step 3.
3. Remove power from the range and disconnect the
wires from the output terminals of the spark module.
Reconnect power and turn one of the valves to the
lite position. If the spark module makes a snapping
noise, the wiring to the igniters is defective. If no
snapping is heard the spark module is defective.
Igniter system works normally for all but one valve:
1. Defective igniter switch on that valve.
Igniter sparks at normal rate with all valves turned
off:
1. Shorted switch or wire. Check each switch with an
Ohmmeter.
Igniter sparks intermittently with all valves turned
off:
1. Defective spark module.
L1
N
Top Burner
Igniter
Switches
Spark
module
Igniters