A fused disconnect switch or a main circuit breaker
(customer furnished) MUST be installed in the
electric supply line for the appliance. It is recom-
mended that this switch/circuit breaker have
lockout/tagout capability. Before making any electri-
cal connections to this appliance, check that the
power supply is adequate for the voltage, amperage,
and phase requirements on the rating plate.
RATING PLATE
The rating plate contains identification and technical
data and is located on the right-hand side panel of the
appliance (Figure 7).
Figure 7
C1
WATER CONNECTION
•
Position the potwasher and level the appliance by
adjusting the appropriate bullet feet (Figure 7).
•
Connect the appliance water supply pipe “A”
(Figure 4/Figure 5/Figure 6)
(keeping
with
local
plumbing codes) to the incoming water supply. Install
a shutoff valve, Y-Strainer and a pressure gauge
between the appliance and the incoming water sup-
ply of the unit (Figure 8).
Figure 8
•
Check that the
dynamic
water supply
pressure
measures
between 7.25 - 101 psi/50 - 700kPa
while
potwasher tank or boiler is filling with water.
If the pressure is too high, install a suitable pressure
regulator on the incoming water supply to the unit.
On models with free-fall drainage:
connect the waste outlet pipe “C” (Figure 4/Figure 5/
Figure 6) to the main drain pipe, using a trap, or place
the outlet pipe over an “S” trap set into the floor.
On models with drain pump:
position the outlet pipe at a height anywhere between 29
1/2” to 39 3/8”/750 and 1000 mm from the floor.
Check that about 1 gallon/4 litres of water flow out of the
outlet pipe during the rinse cycle.
Make sure drain hose does not kink, pinch or twist,
resulting in a water flow restriction.
C2
ELECTRICAL CONNECTION
Figure 9
The installation of this unit must conform to local
codes or, in the absence of local codes, to all Natio-
nal Codes governing plumbing, sanitation, safety
and good trade practices.
•
Check the over rating plate before making any
electric supply connections. Electric supply connec-
tions must agree with data on the unit rating plate.
•
The earth wire at the terminal end must be
3/4”/20 mm (max.) longer than the phase wires.
•
The appliance requires a ground connection to the
unit ground screw located at the rear of the unit
marked “Q” (Figure
4/Figure 5/Figure 6) in the
manual and marked with the symbol “
“ on the unit.
C
INSTALLATION AND START-UP INSTRUCTIONS
Model PW1M
PNC 9CGX 506029 05 Ser.N .123000001
AC 400V 3N 50Hz
Power Boiler 10500w
Power Tank 12000w
Power Max 22000w
Made in EU
Model PW1M
PNC 9CGX506029 05
Ser.N .123000001
!
CAUTION
THE ELECTRICAL CONNECTIONS MUST
MEET ALL NATIONAL AND ELECTRICAL
CODE REQUIREMENTS.
AC
208....
!