ISOLATE MACHINE TO STOP
Running Time too short or too long
Adjust Potentiometer No 1 inside Electrical Control Box (normal factory setting is 2 minutes this
setting is recommended for normal operation)
Adjustable value 30 seconds to 240 seconds possible
Pump is creating loud suction noise
Pump cycle incorrect – Adjust Potentiometer No 2 time
Liquid starvation at sink, check water supply
Pump not delivering water
Check direction of rotation (Counter Clockwise when viewing motor fan)
Problems cleaning the chute
Remove chute from press by loosening thumb screws and clean internal surfaces
Leakage
Remove front panel.
Check for fluid leakage from Disposer, Press and Pump drain holes
Disposer
Pump
Press
Drain Hole Locations Arrowed