Position 9
Drain, calibration of
analogue pressure switch
and spin
Purpose of the test:
To check the correct operation of the spin cycle
drain pump and calibrate the analogue pressure
switch.
Components activated:
•
Door safety interlock
•
Drain
pump
•
Motor up to 650 rpm then at maximum spin
speed (**)
Working conditions:
•
Door
closed
•
Water level lower than anti-boiling level
for spinning
LCD display
Drum speed in rpm/10
Position 10
Drum position
Purpose of the test:
To check the correct position of the drum via DSP
Components activated:
•
Drum rotation motor.
•
door fastening device.
•
Drum position sensor DSP
Working conditions:
•
Door
closed.
LCD display
Position 11
Reading/Deleting the last
alarm
Purpose of the test:
Reading/Deleting the last alarm.
Components activated:
---------------
Working conditions:
---------------
LCD display
(*)
In most cases, this time is sufficient to check the heating. However, the time can be increased by repeating
the phase without draining the water: pass for a moment to a different phase of the diagnostic cycle and
then back to the heating control phase (if the temperature is higher than 80°C, heating does not take
place).
(**)
The check at the maximum speed occurs without control of the A.G.S. (Unbalancing Control Algorithm) and
no garments must be inside the appliance.