background image

Power Unit Location

NOTE: 

Mount power unit at least 12 inches from the ceiling and any adjacent wall, at least 28 inch-
es from the floor and within 6ft. of an electrical outlet.

WARNING: Do not block the hood ventilation openings and duct on the top of the power unit. Lack of venti-

lation will cause the motor to overheat.

WARNING: Do not locate the power unit in a high temperature area where it is inaccessible, for example, an

attic or crawl space.

The power unit should be located as far away from the general living area as possible, yet accessible so you can
remove the dirt receptacle, reach the filter, and inspect the power unit. A typical location would be in a garage where
you could vacuum your car or garage area and where emptying the dirt receptacle and
cleaning the filter would be more convenient. Other suitable locations are in the base-
ment, laundry room, or ventilated storage room. It is recommended that the exhaust be
vented outside; never into a wall, a ceiling, or a concealed space in the house.

Wiring for Power Unit
Place the power unit within six feet of a grounded electric outlet. The unit requires 120
volt, 60 cycle AC power. Be sure you will not overload the circuit.

Install Power Unit
You are now ready to install the power unit. Be sure the power unit will be located at least
12 inches from the ceiling and any adjacent wall and at least 28 inches from the floor.
The motor hood ventilation and safety relief valve should never be obstructed. The unit
must be mounted within 6 feet of a grounded electrical plug. Be sure you will not over-
load the circuit. Check to be sure you will be able to remove the dirt receptacle, reach the
filter, and inspect the power unit.

Compare the distance between the power unit mounting
bracket and the wall studs in the chosen mounting location. If
the mounting brackets cannot mount on the studs, mount two
lengths of boards horizontally between the studs; then mount the
power unit.

Drill the holes and tighten the screws to hang the power unit.
Align the power unit intake fitting to the main trunk line pro-
jecting from the wall. Securely tape each joint, using duct or
electrical tape. DO NOT GLUE. Attach the exhaust pipe to the
motor exhaust if exhausting outdoors.

Connect the two low voltage wires located on the backside of the
power unit to the wires installed with the main trunk line. It is
recommended you secure the connection with wire nuts. Be cer-
tain you comply with your local electrical codes and regulations. Plug the unit into a 120 volt
grounded receptacle. You are now ready to check the installation of the unit:

• Plug the hose into each inlet valve to be sure the electrical contacts operate properly.
• Check each inlet valve for air leaks
• Check each pipe connection for air leaks.
• Be sure the dirt container is properly secured to the power unit.
• Be sure the cartridge filter is properly installed in the power unit.

Your cleaning system is ready to use.

HOW TO USE

The Electrolux Vacuum System is designed to provide the utmost in dust-free, quiet cleaning. The
power unit, which is mounted in a remote area of your home, is connected to centrally located
inlet valves with a system of lightweight plastic pipes. Using the cleaner is as simple as inserting
the vacuum hose into an inlet valve after attaching the appropriate tool.

Summary of Contents for Afuera

Page 1: ...Model Serial www electrolux com ...

Page 2: ...o a properly grounded outlet only refer to Grounding Instructions Do not use extension cords or outlets with inadequate current carrying capacity Turn off all controls before unplugging Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or vacuum cleaner with wet hands Do not put any object into openings Do not use with any opening blocked keep free of dust l...

Page 3: ...s wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the out let reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not change the plug in any way GENERAL INFORMATION The built in vacuum system is designed for dry pick up of household dirt and dust Avoid picking up hard or sharp objects...

Page 4: ...ill not over load the circuit Check to be sure you will be able to remove the dirt receptacle reach the filter and inspect the power unit Compare the distance between the power unit mounting bracket and the wall studs in the chosen mounting location If the mounting brackets cannot mount on the studs mount two lengths of boards horizontally between the studs then mount the power unit Drill the hole...

Page 5: ...ce Dirt Receptacle and Filter Reduced airflow or suction indicates the built in vacuum system is not operating at maximum efficiency If the dirt receptacle is full and the filter is clogged no air can pass through the unit and no cleaning can take place Empty The Dirt Receptacle NOTE Disconnect power cord from electrical outlet before removing the dirt receptacle Some models feature see through wi...

Page 6: ...e at the second inlet the blockage is in the hose To clear the hose obstruction insert a blunt instrument into the hose garden hose wood dowel If there is one inlet valve without normal suction and you have checked for hose blockage then the blockage is in the pipe system between the blocked inlet valve and the power unit see instructions below Clear blockage in pipes Insert the hose into the inle...

Reviews: