Overload-Protection Reset Button
The built-in vacuum system features an overload protection (circuit breaker) which can be reset should the motor be
overloaded causing the circuit to open. Should this happen and the power unit fails to operate, depress the reset but-
ton which is located on the side of the power unit. If the protector continues to trip; contact the authorized service
center nearest you.

Inlet Valves
Each inlet valve has electrical contacts which activate the power unit motor when the hose is connected. The low volt-
age wires attached to the inlet activate the power unit when the hose cuff is inserted. The system shuts off as soon as
the hose is removed. 

An obstruction in the inlet valve may cause the power unit to continue to run after the hose is removed from the inlet.
Check all the inlet valves and remove any obstruction to shut down the power unit.

When unplugging the hose from the inlet valve, hold the inlet cover open for
a few seconds to allow the suction to decrease and protect the inner seal.

HOW TO MAINTAIN

The instructions given in the booklet serve as a guide to routine maintenance.
Proper airflow or suction can be maintained by keeping the dirt container and
filter clean and the plastic pipe and hose free from clogs. Check the Home
Maintenance Section at the end of this booklet for suggestions before calling
for service.

Dirt Receptacle and Filter

Reduced airflow or suction indicates the built-in vacuum system is not operating at maximum efficiency: If the dirt
receptacle is full and the filter is clogged, no air can pass through the unit and no cleaning can take place.

Empty The Dirt Receptacle

NOTE:  Disconnect power cord from electrical outlet before removing the dirt receptacle.

Some models feature see-through windows on the receptacle to tell at a glance when the receptacle needs to be emp-
tied; on other models the receptacle must be removed. To remove the receptacle, grasp the handles and turn the recep-
tacle to the left. Remove and empty the contents. Return the receptacle and turn to the right. Be sure the receptacle
is securely attached to avoid any suction leakage.

Filter Cleaning

If the filter is clogged, no air can pass through the unit and no cleaning will take place. For best
performance removable filter should be cleaned every 3 years or when you notice a decrease in
suction performance.

NOTE: Do not operate this unit without filter in place.

NOTE: Disconnect power cord from electrical outlet before cleaning the filter.

1. Remove the dirt receptacle.
2. Wrap large garbage bag around lower portion of the power unit and hold firmly in place.
3. Grasp loose debris from surface of filter through the plastic bag, remove bag and discard.
4. Grasp filter on the bottom end cap and pull straight down.

5. Clean by tapping filter firmly against the inside of a trash

can or on a hard surface striking the plastic end cap.

6. Clean until dirt stops falling from the filter.

Summary of Contents for Afuera

Page 1: ...Model Serial www electrolux com ...

Page 2: ...o a properly grounded outlet only refer to Grounding Instructions Do not use extension cords or outlets with inadequate current carrying capacity Turn off all controls before unplugging Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or vacuum cleaner with wet hands Do not put any object into openings Do not use with any opening blocked keep free of dust l...

Page 3: ...s wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the out let reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not change the plug in any way GENERAL INFORMATION The built in vacuum system is designed for dry pick up of household dirt and dust Avoid picking up hard or sharp objects...

Page 4: ...ill not over load the circuit Check to be sure you will be able to remove the dirt receptacle reach the filter and inspect the power unit Compare the distance between the power unit mounting bracket and the wall studs in the chosen mounting location If the mounting brackets cannot mount on the studs mount two lengths of boards horizontally between the studs then mount the power unit Drill the hole...

Page 5: ...ce Dirt Receptacle and Filter Reduced airflow or suction indicates the built in vacuum system is not operating at maximum efficiency If the dirt receptacle is full and the filter is clogged no air can pass through the unit and no cleaning can take place Empty The Dirt Receptacle NOTE Disconnect power cord from electrical outlet before removing the dirt receptacle Some models feature see through wi...

Page 6: ...e at the second inlet the blockage is in the hose To clear the hose obstruction insert a blunt instrument into the hose garden hose wood dowel If there is one inlet valve without normal suction and you have checked for hose blockage then the blockage is in the pipe system between the blocked inlet valve and the power unit see instructions below Clear blockage in pipes Insert the hose into the inle...

Reviews: