background image

air-o-steam

Touchline

Natural Gas Combi Oven 101

air-o-steam

Touchline Natural Gas Combi Oven 101

The company reserves the right to make modifications to the products

without prior notice. All information correct at time of printing.

2012.09.28

Front

Top

CWI

= Cold Water inlet 

D

= Drain

EI

= Electrical connection

G

= Gas connection

Side

Electric

Supply voltage:

267702(AOS101GTG1)

230 V/1N ph/50/60 Hz 

Circuit breaker required

Gas

ISO 7/1 gas connection diameter:

1/2" MNPT 

Natural gas:

 

Pressure:

7" w.c. (17.4 mbar) 

 

Steam generator:

20 kW 

 

Heating elements:

68180 BTU (20 kW) 

 

Total thermal load:

119315 BTU (35 kW) 

Water:

Water inlet "CW" connection:

3/4" 

Water inlet "FCW" connection:

3/4" 

Total hardness:

5-50 ppm 

Pressure:

1.5-4.5 bar 

Pressure:

15-36 psi (1.5-4.5 bar) 

Drain "D":

1"1/4 

Electrolux 

 recommends the use of treated water, based on

testing of specific water conditions.
Please refer to user manual for detailed water quality
information.

Installation:

Clearance:

5 cm rear and right hand sides. 

Suggested clearance for service
access:

50 cm left hand side. 

Capacity:

GN:

10 - 1/1 Gastronorm 

Max load capacity:

50 kg 

Key Information:

Net weight:

160 kg 

Shipping weight:

180 kg 

Shipping height:

1270 mm 

Shipping width:

990 mm 

Shipping depth:

950 mm 

Shipping volume:

1.19 m³ 

Summary of Contents for air-o-steam Touchline Natural Gas Combi Oven 101

Page 1: ...le Low Temperature Cooking cycle LTC to minimize weight loss maximizing food quality for large pieces of meat Reheating cycle efficient humidity management to quickly reheat Proofing cycle uses the air o clima function to create the perfect proofing conditions Programs mode a maximum of 1000 recepes can be stored in the oven s memory to recreate the exact same recepe at any time 16 step cooking pr...

Page 2: ...rotection certification for easy cleaning 304 AISI stainless steel construction throughout Seamless hygienic cooking chamber with all rounded corners for easy cleaning Double thermo glazed door with open frame construction for cool outside door panel Swing hinged easy release inner glass on door for easy cleaning Swing hinged front panel for easy service access to main components Integrated spray ...

Page 3: ...ator 20 kW Heating elements 68180 BTU 20 kW Total thermal load 119315 BTU 35 kW Water Water inlet CW connection 3 4 Water inlet FCW connection 3 4 Total hardness 5 50 ppm Pressure 1 5 4 5 bar Pressure 15 36 psi 1 5 4 5 bar Drain D 1 1 4 Electrolux recommends the use of treated water based on testing of specific water conditions Please refer to user manual for detailed water quality information Ins...

Page 4: ...4 edges aluminium 400x600x20 PNC 922191 Standard open base with tray support for 6 10x1 1GN PNC 922195 Basket for detergent tank wall mounted PNC 922209 Holder for detergent tank to mount on open base PNC 922212 Frying griddle GN 1 1 PNC 922215 Cupboard base and tray support for 6 10x1 1GN ovens PNC 922223 Hot cupboard base with humidifier for 6 10x1 1GN ovens with support for 1 1GN and 600x400mm ...

Reviews: