Technical data
Dimension of the recess
Height
1600 mm
Width
600 mm
Depth
645 mm
The technical information are situated in the
rating plate on the internal left side of the ap-
pliance and in the energy label.
Installation
Read the "Safety Information" carefully
for your safety and correct operation of
the appliance before installing the
appliance.
Positioning
Install this appliance at a location where the
ambient temperature corresponds to the cli-
mate class indicated on the rating plate of the
appliance:
Climate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Location
The appliance should be installed well away
from sources of heat such as radiators, boil-
ers, direct sunlight etc. Ensure that air can
circulate freely around the back of the cabi-
net. To ensure best performance, if the ap-
pliance is positioned below an overhanging
wall unit, the minimum distance between the
top of the cabinet and the wall unit must be
at least 100 mm . Ideally, however, the ap-
pliance should not be positioned below over-
hanging wall units. Accurate levelling is en-
sured by one or more adjustable feet at the
base of the cabinet.
If the cabinet is placed in a corner and the
side with the hinges facing the wall, the dis-
tance between the wall and the cabinet must
be at least 10 mm to allow the door to open
enough so that the shelves can be removed.
Warning!
It must be possible to
disconnect the appliance from the mains
power supply; the plug must therefore
be easily accessible after installation.
10mm
10mm
100mm
Electrical connection
Your appliance must be connected to a sin-
gle-phase supply of 230 V. Check that the
electricity meter is suitable for the power con-
sumed by your appliance, allowing for the
other connected appliances. Rating of the in-
line fuses (one per phase): 10 A at 230 V.
Important!
Installation must be done in
conformance with the applicable codes, the
requirements of the standard NF.C.15100
and the requirements of the electrical energy
supplier.
Use a power supply socket that has an earth
connection and this must be connected in
conformance with the standard 15100 and
the requirements of the supplier of electrical
energy. this power supply socket must be
electrolux