Installation
Include the possibility in the planning that adjustments
may need to be made to the loop. In doing so
remember:
•
Leave a few extra metres of wire at the beginning
and end, close to the charging station.
•
Place a few extra metres of wire about every
30 metres around the entire loop.
All extra wire should be laid in tight, parallel loops.
If staples are used, the parallel loops should be
placed under the same staple.
Remember the following with regard to the working
area boundaries:
•
If a high obstacle, for example a wall or fence,
borders the working area, the boundary wire should
be laid 35 cm from the obstacle. This will prevent
the Automower™ from colliding with the obstacle
and reduce body wear.
•
If the working area borders against, for example,
pools of water the boundary wire should be
supplemented with a fence or the like. The height
must then be at least 15 cm. This will prevent the
Automower™, under any circumstances, coming
outside of the working area.
3012-138
IMPORTANT INFORMATION
Extra wire must not be placed in coils outside
the boundary wire. This can disrupt the
Automower™.