15
Cruise chilling cycle
The chilling process starts when the food probe reach the value 70°C; the cell
temperature decrease to -2°C (SOFT Cycle), so the compressor works using its
normal duty cycle to keep the cell temperature at this value.
If
T
fp
< T
n
The food probe temperature has a trend shown on the diagram: its curve is less
than the chilling curve and the logic controls checks each minute if this
temperature reach the first point A.
If
T
fp
> T
n
If the food probe temperature reach the value
T
n
than the algorithm decide that
its time to start the compressor in order to decrease the cell temperature till the
value -11°C. The food temperature change its trend staying under the chilling
curve.
If necessary the electronic controls can decide to change further the cell
temperature at
-20°C
to reach the food temperature
+3°C
in
90
mins.