ERROR CODE E13:
REAL TIME CLOCK FAILURE
Picture 1: ERROR CODE E13
When happens an Alarm due to Real time clock failure the red Alarm
Service led is flashing and the buzzer is active. The display on the user
interface shows the
ERROR
codes E13
(see Picture 13).
This type of error causes the following possible events:
¾
The electronic control looses data and time setting values.
Check all of User’s parameters and if is necessary regulate them
Following this sequence: months -year- Days – hours- minutes.
¾
Internal battery is completely discharged and the main board can’t
save anything in the data storage.
SWICTH OFF ALARMS :
SET THE DATA
OR
REPLACE THE MAIN BOARD
- 76 -