5 - Slide off the water drain pipe from the silicone connection, releasing the fixing clamp with pliers
(see Fig. 251).
Fig.
251
1 - WATER TANK
2 - STEAM GENERATOR
3 - FIXING CLAMP -
SILICONE CONNECTION -
TANK
4 - FIXING CLAMP -
SILICONE CONNECTION -
DRAIN PIPE
5 - SILICONE CONNECTION -
6 - FIXING CLAMP -
SILICONE CONNECTION -
STEAM GENERATOR
7 - WATER DRAIN PIPE
8 - WATER DRAIN PIPE
FIXING
SCREW
Fig.
252
1 - WATER TANK
2 - EXPANSION CHAMBER
3 - THERMOSTAT ASSEMBLY -
STEAM
GENERATOR
4 - ELECTRICAL CONNECTION
FOR STEAM GENERATOR
ASSEMBLY
5 - THERMOSTAT ASSEMBLY
FIXING
SCREW
6 - STEAM GENERATOR
7 - OVERFLOW PIPE
FIXING
SCREW
8 - SILICONE CONNECTION -