SOI 02.10 FV
132/142
599 70 59-01
3.7 -
ACCESSING THE TEMPERATURE SENSOR IN ELECTRONIC MODELS
In electronic models, in order to access the temperature control sensor, proceed as follows:
1 - Remove the tank + steam generator assembly as illustrated in chapter 3.1.
2 - Detach the connection connector from the temperature sensor.
3 - Unscrew the fixing screws on the sensor.
4 - Extract the sensor from its housing.
Fig.
274
1 - STEAM OUTLET PIPE
2 - TEMPERATURE SENSOR
PT500
3 - FIXING SCREW FOR THE
SENSOR
4 - TEMPERATURE
SENSOR CONNECTION
CONNECTOR
5 - EXPANSION CHAMBER