background image

•   Remove the  lower trim  moulding  and 

then 

withdraw  the 

panel  by  sliding  it 

d

ownwards. 

•   Fit 

new  panel  in 

place 

and  slide  it  up  as  far  as  possible. 

•   Fit 

the 

trim 

moulding  back 

in 

place. 

BUILD

ING

-IN 

The 

refrigerator is 

intended  for  in

stal

lation  in 

a caravan  or 

motorhome,  and  the  description  relates  to 

this 

application. 

The 

refrigerator must 

n

o

be  exposed  to  radiated  heat from 

hot  objects 

(e.g. 

below a cooker without  proper 

heat 

shiel­

ding). 

E

xcess

ive  heat 

irradiation 

impairs 

performance and  leads 

to 

increased  energy consumption. 

For 

this  reason  the  refrige­

rator  should 

be 

installed  if  possible 

not 

at  the 

entrance 

side 

of 

the 

vehicle 

-

normally orientated  south  and  often 

with 

an 

awning 

which 

would  impair the  dispersion 

of 

heat  and 

combustion  gases from  the 

ventilation 

openings. 

It  is  not  a good  practice  to  install  the  refrigerator  so  that 

the 

vent 

openings 

are 

covered  by  the  vehicle's  entrance  door 

when  this 

is 

open. 

Thi

would  reduce 

the 

ventilation  air 

fl

ow 

to 

the  cooling 

unit 

and 

reduce  refrigeration 

performance. 

The enclosure 

The  refrigerator 

must  be  installed 

in  an 

enclosure, 

the 

dimensions of  which  are  shown 

in 

TECHNICAL DATA. 

The 

bottom  of  the  enclosure 

must  be  horizontal 

and  even 

so 

that  the  refrigerator 

can 

be 

easily 

pushed  into 

place. 

It 

must  be  sturdy  enough 

to 

carry  the  wieght  of  the  refrigera­

tor. 

Battens  must 

be 

installed  at the 

enclosure 

and  fitted  with 

sealing 

s

trips, 

as shown 

in  fig

4

Slide  in 

the  refrigerator  until  it 

is 

flush 

with 

the 

front 

of 

the 

recess. 

There 

must 

be  10-20 

mm  free  space  behind 

the 

refrigerator. 

Four  fasteners 

are 

fitted  in  plastic  bushings  in  the 

side  walls 

of 

the 

fridge,  fig 

7. 

They 

are 

used 

for 

s

ecuring 

the  refrigera­

to

in 

the  enclosure. 

The  side  walls 

of 

the 

enclosure  and/or any 

wooden  braces 

installed  to  hold 

the 

refrigerator must 

be  dimensioned  to 

seat 

the  screws 

secure

ly, 

also  considering  the  forces  due  to 

the  movement 

of 

the 

vehicle. 

With  the  refrigerator in 

place,  drive 

the 

screws 

through  the 

bushings 

in 

the  lining  of  the  refrigerator  into  the  walls  of  the 

enclosure  (fig.7). 

There 

must  not 

be 

more 

than 

3mm  of 

clearance 

between 

refrigerator and  enclosure on  each  side. 

If  neces

sa

ry, 

wooden  strips  or  similar should  be  fitted. 

Note: 

This 

is  the  only approved  means  of 

securing 

the 

refrigerator  to  the 

enclosure  and 

to  the 

vehicle. 

Fasteners 

penetrating  other  parts 

of 

the  insulation 

(PU)  foam 

of  the 

refrigerator  might 

damage components 

like  electric wiring 

etc. 

VENTILATION  OF THE  UNIT 

At 

high  ambient temperatures 

the  refrigeration 

unit will  only 

perform  adequately 

when  properly  ventilated. 

The  refrigeration  unit 

is  ventilated  via  two  openings 

in 

the 

wall 

of  the 

caravan 

(see 

fig. 

5). 

Fresh 

air 

enters 

through  the 

lower 

opening  and  warm  air 

i

discharged 

through  the  upper 

one. 

Locate  the  lower opening  immediately 

above  the  floor  of  the 

recess,  and  the  upper one 

as 

high 

as 

possible  above  the 

condenser (C)  of 

the  refrigeration  unit

at 

least 

as shown  in 

fig. 

6b  but 

preferably 

as  shown  in  fig.  6a. 

Ventilation  grilles  Fig.  2 

The 

openings  in 

the 

caravan  wall 

must 

be 

fitted  with  the 

Electrolux 

ventilation  systems

Fitting 

the 

grilles,  model 

A 1620, 

which 

were  specially 

developed  by 

Electrolux  for 

this  purpose  (shown  as 

in 

fig. 

6). 

It 

is  a good  idea

to  install  the  frame 

R  1640 

(A 

in 

the 

same  figure), 

at 

the 

same 

time.  Then  the  grilles 

can  be 

easily  removed  which  permits  inspection  and  small 

repairs 

to 

be carried  out 

without the necessity 

for  removing  the 

refrigerator  from  the 

recess. 

If 

there  is 

no 

outer grille  at  floor  level  where  leaking  gas can 

escape,  a 40 mm 

hole 

to  the  outside  should  be 

made in  the 

floor 

of 

the  recess  to 

drain 

any  unburnt 

gas 

to  the  outside 

gas. 

Fit 

the  hole  with  wire  mesh  and  an  angled  plate 

to 

protect 

from 

stones,  mud 

etc

Removal  of flue  gases 

The 

ventilation  passage  at 

the 

rear  of  the  recess, 

between 

the 

outer wall  of 

the 

vehicle  and 

the  refrigerator 

(fig.  6) 

is 

sealed  off 

against 

the  living 

space,  and 

so 

cold 

draughts are 

excluded  (winter camping)  and  no flue  gases  can  penetrate 
into 

the 

vehicle. 

Thus 

special 

flue 

outlet  is 

no  longer 

necessary 

-

the  gases 

are 

dispersed  through  the  upper vent 

grille. 

Note: 

With  this  mode 

of 

installation  the  same  type  of  grilles 

(without an  integrated  flue  outlet),  should  be  installed 

at 

the 

upper 

as well  as at 

the  lower 

vent open-ning

The 

angled 

T-piece 

for 

the 

flue  tube  (when  delivered)  should  not  be 

used  in  this 

case. 

The top 

of 

the 

enclosure above 

the  flue  tube 

(I), 

fig 

6, 

should  be 

covered  with 

aluminum 

sheet 

metal

as  indicated 

in  (B),  to  facilitate 

the 

heat dispersion. 

In  fig 

6 the 

letters  have 

the 

following 

meaning: 

A

Frame 

R 1640 

for  the 

grilles 

B

.  

Aluminum 

cladding 

C. 

Condenser 

of  cooling 

unit 

D

.  

Vent 

grill 

A 1620 

E

Sealing  profile  (optional  extra) 

Width 

486 

mm 

Electrolux art.  nr.  295  1147-10 

F. 

Refrigerator 

rear  wall 

G.  

Wooden 

batten 

approx.  10 

x 20 

mm 

(se

e  fig 

4) 

H.  Height  of  the 

enclosure 

(see 

TECHN

ICA

DATA) 

I. 

Flue 

tube 

LP  GAS  C

ON

NECT

IO

CAUTION!  CHECK THAT THE GAS  SUPPLIED TO 

THE  REFRIGERATOR  IS  AT  TH

COR

R

ECT 

PRESSURE.  SEE THE  REDUCING  VALVE 

ON 

T

HE 

LP  GAS CONTAINER 

The 

refngerator 

IS 

designed  for 

operation 

on 

LP 

gas 

of 

Butane  type 

the 

pressure 

of 

which  must 

be  28 

mbar 

for 

Butane  and  37 

mbar for 

Propane. 

11 

Summary of Contents for CARAVAN RM 4270

Page 1: ...Electrolux CARAVAN RM 4270 RM 4271 Typ C40 110 T B 06 99 821 2663 03 CE ...

Page 2: ...ot later than seven days after the refrigerator was delivered DATA PLATE Check the data plate inside the refrigerator to ensure that you have received the right model The right gas pressure is 30 mbar The right voltage is 230 volts The data plate contains e g the following details Model designation RM Product number Serial number Since these details will be needed if you have to contact service pe...

Page 3: ...ng stops automatically and the switch stops flashing 8 Keep the 0 button pressed for a further 10 to 15 secon ds to active the flame failure device then release it If you have Model RM 4270 proceed as follows 3 Turn on the gas supply by pressing the 0 knob and turning it to the position 4 Set the thermostat knob E to the highest setting 5 Keeping the flame failure device buttom 0 pressed operate t...

Page 4: ... the ice The defrost water runs from a collector channel to a recep tacle at the rear of the refrigerator where it evaporates Defrost water in the freezer compartment should be mop ped up with a cloth When the ice has melted wipe the refrigerator dry and restart it Place the food items back inside but wait until the refrigerator is cold before making ice cubes CLEANING THE REFRIGERATOR Clean the i...

Page 5: ...teed for one full year on condition that it is used in a correct manner and in accordance with these operating and installation instructions It is also embraced by a European guarantee as described in the brochure supplied with the refrigerator Service and spare sparts are obtainable from your dealer or Electrolux consult the telephone directory TECHNICAL DATA RM 4270 71 Overall dimensions refrige...

Page 6: ...ratures the refrigeration unit will only perform adequately when properly ventilated The refrigeration unit is ventilated via two openings in the wall of the caravan see fig 5 Fresh air enters through the lower opening and warm air is discharged through the upper one Locate the lower opening immediately above the floor of the recess and the upper one as high as possible above the condenser C of th...

Page 7: ...cted to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured red 3 amp fuse In other countries the fus...

Reviews: