Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply.
Charcoal Filters
In the recirculation mode the charcoal
fi
lters absorb smells and unwanted odours.
Enabling the alarm signal
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date.
• Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply.
• Restore the connection by pressing and holding T1.
• Release the button. All
fi
ve LEDs are turned on
• Within 3 seconds press T1 until LEDs T1 and T4
fl
ash in con
fi
rmation:
• LED
fl
ashes twice - Activated charcoal
fi
lter saturation alarm ENABLED
• LED
fl
ashes once - Activated charcoal
fi
lter saturation alarm DISABLED
The
fi
lter is not washable and cannot be regenerated. It must be replaced when led S1
fl
ashes or at least every
4 months. The alarm signal will only light up when the extractor motor is switched on.
To Remove/Replace the Charcoal Filters
• Remove the metal grease
fi
lters
• Remove the saturated activated carbon
fi
lter by
releasing the
fi
xing hooks
• Fit the new
fi
lter by hooking it into its seating
• Replace the metal grease
fi
lters.
This appliance can be a possible
fi
re
hazard if the grease and charcoal
fi
lters
are not cleaned and replaced as recommended.
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the
leds start to
fl
ash.
Changing the Light halogen
• Remove the snap-on lamp cover by levering it from
under the metal ring, supporting it with one hand.
• Remove the halogen lamp from the lamp holder by
pulling gently.
• Replace the lamp with a new one of the same type,
making sure that you insert the two pins properly into
the housings on the lamp holder.
• Replace the snap-on lamp cover.