4 www.electroluxaircomfort.com
the air discharge area or front grill of the unit.
• Do not start or stop the dehumidifi er by
unplugging the power cord or turning off the
power at the electrical box.
• Do not cut or damage the power cord. If the
power cord is damaged, it should only be
replaced by an authorized Electrolux servicer.
• In the event of a malfunction (sparks, burning
smell, etc.), immediately stop the operation,
disconnect the power cord, and call an
authorized Electrolux servicer.
• Do not operate the dehumidifi er with wet
hands.
• Do not pull on the power cord.
• Do not drink any water from the dehumidifi er.
Caution!
Avoid Injury or damage to the unit or other
property
• Do not direct airfl ow at fi replaces or other
heat related sources as this could cause fl are
ups.
• Do not climb on or place objects on the unit.
• Do not hang objects off the unit.
• Do not place containers with liquids on the
unit.
• Turn off the dehumidifi er at the power source
when it will not be used for an extended
period of time.
• Operate the unit with air fi lter in place.
• Do not block or cover the intake grill,
discharge area and outlet ports.
• Ensure that any electrical/electronic
equipment is one yard away from the unit.
• Do not use or store fl ammable gases near
the unit.
BEFORE FIRST USE
Selecting a location
Important!
1. Dehumidifi er must be operated in an
enclosed area to be most effective. Close all
doors, windows, and other outside openings
to the room. The effectiveness of the
dehumidifi er depends on the rate at which
new moisture-laden air enters the room.
2. Place dehumidifi er in a location that does not
restrict airfl ow through the front of the unit or
out of the louvres on the left side of cabinet.
3. A dehumidifi er operating in a basement will
have little or no effect in drying an adjacent
enclosed storage area, such as a closet,
unless there is adequate circulation of air in
and out of the area. lt may be necessary to
install a second dehumidifi er in the enclosed
area for satisfactory drying.
4. The dehumidifi er must be installed on a level
fl oor that will support it with a full bucket of
water.
5. There should be a minimum of 12 inches
clearance around the dehumidifi er.
How it works
When the unit is started, the fan begins to pull
moisture-laden air across the dehumidifying
coils. The coils condense or draw moisture
from the air, and air fl ows through the side
louvres into the room as dry, warm air. Moisture
removed from air is collected in a bucket on the
front of the dehumidifi er.
The unit is designed to operate between
5°C (41°F) and 35°C (96°F). The unit will not
work properly if the temperature is out of this
temperature range, or the performance of the
unit will fall greatly.
The “Compressor” circuit has an automatic 3
minute time delayed start if the unit is turned off
and on quickly.
This prevents overheating of the compressor
and possible circuit breaker tripping. Make sure
the tank is fi tted correctly otherwise unit will not
turn on.