background image

12

Installation manual

4.2

Back piece

1

1

fig.W01314

Box 1

Bag / Quantity

1

2

3

4

5

6

7

8

9

1

M6x10

11x

Summary of Contents for DC6-14HP

Page 1: ...Installation manual Drying Cabinet DC6 14HP Original instructions 427001217 EN 2022 03 18 ...

Page 2: ......

Page 3: ...ces 13 4 4 Roof 13 4 5 Doors 14 4 6 Door adjustment 15 4 7 Wall bracket 16 4 8 Glove hanger 17 4 9 Lint filter 18 4 10 Hanger assembly 19 4 11 Hanger installation 21 4 12 Installing the heat pump component on the cabinet 22 4 13 Install the control panel 23 5 Electrical connection 24 5 1 Network Functions 25 6 Condensation connection 27 7 Function check 28 8 Disposal information 29 8 1 Disposal of...

Page 4: ......

Page 5: ...supervision or instruction con cerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Additional requirements for other countries This appliance is not intended for use by persons including children with reduced physical sensory or mental ca pabilities ...

Page 6: ...tion manual 2 Technical data 2 1 Dimensions drawing A C D G F E I J B fig W01309 A B C D E F G I J mm 1805 800 1805 875 1560 900 2245 850 1180 Condensation outlet 32 see page 13 Electrical connection see page 12 ...

Page 7: ...68 dB A Average heat emission per drying cycle used to assess ventilation need 1 2 kW For assistance with dimensioning necessary ventilation needs contact authorized ventilation technician For suffi cient ventilation all sources introducing heat need to be taken into account plus all other parameters effecting the ventilation need Climate zone building parameters room size etc This product contain...

Page 8: ...led upon delivery The cabinet component and heat pump components are delivered in a single package 3 1 Transport unit The transport unit contains 5 boxes with the content described below 1950 1040 1150 310 kg fig W01310 Box no Contents 1 Small components minor plate pieces all documentation See page 9 2 Bottom Left Door Left Back Plate Right Back Plate 3 Right Door Top Right Side Plate Left Side P...

Page 9: ...x 9 fig W01311 1 User Manual OM Installation Manual IM Assembly Instructions Wiring Diagram Disposal Instructions 3 3 Recommended tools 3 2 1 4 5 fig W01312 1 Bits Torx T10 T20 T25 T30 Allen key 4 0 2 Socket 10 mm and 13mm 3 Fixed wrench 7mm 4 Slotted screwdriver 0 5 x 3 5 Slotted screwdriver 8 x 150 Other tools as illustrated ...

Page 10: ... holes of the ad justable feet See the next chapter 3 5 Ventilating the room When the machine is in operation the room temperature increases Due to this the room must have sufficient ventilation All sources introducing heat into the same room requires to be considered when dimensioning the ventilation Heat sources could for example be more tumble dryers drying cabinets washers ironers radiators et...

Page 11: ...embly instructions 4 1 Bottom plate 2 3 6 1 5 6 7 8 1 2 3 4 fig W01313 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 Cover plug 1x 2 M4x12 4x 3 End cap 1x 4 Cover plug 5x 5 Lock nut M4 2x 6 Magnetic holder 1x 7 Magnet 2x 8 Foot screw 6x ...

Page 12: ...12 Installation manual 4 2 Back piece 1 1 fig W01314 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 M6x10 11x ...

Page 13: ...manual 13 4 3 Side pieces 1 1 2 fig W01315 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 M6x10 10x 2 M6x10 12x 4 4 Roof 1 2 1 2 1 3 fig W01316 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 M6x10 16x 2 Cover 2x 3 RTK B8 4 2x6 5 8x ...

Page 14: ...14 Installation manual 4 5 Doors 2 3 1 1 2 4 fig W01317 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 Lock nut 2x 2 Magnet 2x 3 M4x12 4x 4 Handle 1x ...

Page 15: ...Installation manual 15 4 6 Door adjustment 1 I II III IV V 2 fig W01318 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 Washer 7x12x1 5 6x ...

Page 16: ...16 Installation manual 4 7 Wall bracket 1 4 1 2 3 2 fig W01319 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 M6x16 4x 2 Lock washer 6 4x11x0 7 4x 3 Washer 16x6x1 4x 4 Wall bracket 4x ...

Page 17: ...Installation manual 17 4 8 Glove hanger 8 3 4 2 3 1 fig W01320 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 M5x14 4x 2 Plastic washer 5 3x15x1 2 4x 3 Washer 5x13x1 8x 4 Nylock M5 4x ...

Page 18: ...18 Installation manual 4 9 Lint filter 1 4 9 2 3 fig W01321 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 Screws 4x 2 Filter holder 1x 3 Lint filter 1x The filter is held by 4 screws and a filter holder ...

Page 19: ...Installation manual 19 4 10 Hanger assembly 1 4 2 3 4 fig W01322 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 Plastic washer 8x25x1 5 8x 2 Washer 8x25x1 5 8x 3 Lock nut M8 4x 4 M8x75 4x ...

Page 20: ...20 Installation manual 1 2 3 4 fig W01323 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 Metal screw 4 32x32 1x 2 Washer 4x10x1 1x 3 Door stop 1x ...

Page 21: ...ation manual 21 4 11 Hanger installation 6 I II III 3 1 2 4 fig W01324 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 Spacer plate 2x 2 Chapter 4 4 Roof 3 Upper bracket 1x 4 Lower bracket 1x X X X 0 2x IV X fig W01325 ...

Page 22: ...ws with washers Adjust the adjustable feets on the heat pump part to match the screws holding the heat pump to the body Fasten the heat pump with 8 screws with washers Verify that the adjustable feets are screwed down to the floor Box 1 Bag Quantity 1 2 3 4 5 6 7 8 9 1 Screw M6S 10x30 8x 2 Washer BRB 10 5x21x2 8x 3 Screw 8x 4 Washer 8x ...

Page 23: ...Installation manual 23 4 13 Install the control panel 1 1 fig W01327 Box 1 Bag Quantity 1 2 3 4 5 6 7 8 1 4x9 5 SHEETtracs 4x ...

Page 24: ...ommend that the mains cable be equipped with a ground fault interrupter The manufacturer disclaims all liability if the electrical connection is not done in the manner prescribed in this manual Connection to the mains must be via an all pole switch to 400V 3N AC 50Hz Heating options Mains voltage Hz Total output kW Recommended fuse Heat pump 400V 3N 50 3 2 10A slow blow 10A automatic fuse Unscrew ...

Page 25: ...program buttons press Stop Use the program buttons to move to Parameter 117 and enter the parameter using the Stop button Select the baud rate that matches the setting in ELS Vision 0 off 1 2400 bps 2 4800 bps 3 9600 bps Use the Stop button to exit the parameter Then access parameter 118 and set network address 1 127 To confirm the new settings Press the Stop button and then Butterfly Connecting t...

Page 26: ...meter value to 1 This will activate the cabinet for network use Use the Stop button to exit the parameter To confirm the new settings Press the Stop button and then Butterfly Restore factory settings To restore the electronics to factory settings Press the Stop button and then press both program buttons The display shows FACT DEFS ...

Page 27: ...ection The condensation outlet is located under the heat pump component as illustrated in the form of a pipe with a 32 mm diameter Connect a suitable hose and route it to the floor drain 1 fig W01329 1 Pipe connection for condensation dia 32 mm ...

Page 28: ...henever a repair has been made a function check must be performed before the appliance can be used again Select any program and check that the drying cabinet is heating and that there are no odd noises Ready for use If all tests are OK the appliance is now ready for use If any of the tests fail or deficiencies or faults are detected please contact your local service organization or supplier ...

Page 29: ...cycled and that the refrigerator and heat pump components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste but must be correctly disposed of in order to prevent any negative consequences for the environment and human health For further information on the recy cling of this product contact the local dealer o...

Page 30: ......

Page 31: ......

Page 32: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...

Reviews: