Installation manual
7
2.2
Technical data
Capacity:
max. 10 kg of laundry
Drainage capacity:
80 g/min (10 kg 55% residual moisture)
Electrical connection:
400V 3N AC 50Hz
Fuse 10A slow-blow, 10A automatic fuse.
Power:
3.2 kW
Hanging length:
22 meters
Dimensions:
Height
1805 mm
Width
2240 mm (including heat pump)
Depth
800 mm
Weight:
250 kg (for assembled cabinet)
Sound level:
Airborne sound level at full load 68 dB (A)
Average heat emission per drying cycle used to assess
ventilation need*:
1.2 kW
* For assistance with dimensioning necessary ventilation needs, contact authorized ventilation technician. For suffi-
cient ventilation all sources introducing heat need to be taken into account plus all other parameters effecting the
ventilation need. Climate zone, building parameters, room size, etc.
This product contains fluorinated greenhouse gases. Hermetically sealed.
Type of refrigerant:
R134a
Refrigerant quantity:
1.5 kg
Total factor for global warming potential:
1430
CO
2
equivalent:
2.145 tonnes
Leak test:
28 bar
Summary of Contents for DC6-14HP