Installation manual
17
7 Connection to floor drain
1
2
3
fig.W01390
Cabinet as view from behind with condensation hose attached
1
Hose nipple
2
Hole for hose in both sides of the cabinet
3
Alternative hole for hose in both sides of the cabinet
The cabinet is delivered from the factory with a condensation drain connection on the rear of the cabinet. Thread the
supplied condensation hose on the hose nipple and route it to the floor drain. Thread on the hose without hose clip. A
3 m hose is found in the installation kit.
In the rear edge of the cabinet’s sides, there are 2 holes on each side. Choose a suitable hole for routing the hose so
that it forms a smooth arch and there are no kinks.