service data sheet
242007200
reFriGeratOr draWers - r134a
impOrtant saFety nOte
The information provided herein is designed to assist qualified repair
personnel only. Untrained persons should not attempt to make repairs
due to the possibility of electrical shock. Disconnect power cord before
servicing this appliance.
impOrtant
If any green grounding wires are removed during servicing, they must
be returned to their original position and properly secured.
cautiOn
all electrical parts and wiring must be shielded from torch flame.
dO nOt allow torch to touch insulation; it will char at 200°F
and flash ignite (burn) at 500°F. excessive heat will distort the
plastic liner.
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS
AT MID-POINT CONTROL SETTING
type a with run/start
capacitor
65°F (18°c) ambient
90°F (32°c) ambient
Operating Time
N/A
30 to 50%
Temperature
34º F to 45º F
34º F to 45º F
Low Side Pressure
(cut-in)
30 to 45 psig
208 to 310 kPa
30 to 45 psig
208 to 310 kPa
Low Side Pressure
(cut-out)
-2 to 4 psig
-14 to 28 kPa
-2 to 4 psig
-14 to 28 kPa
High Side Pressure
(last 1/3 cycle)
90 to 120 psig
621 to 827 kPa
130 to 175 psig
896 to 1207 kPa
Wattage (last 1/3 cycle)
85 to 125
85 to 125
Amps (running)
.75 to 1.2
.75 to 1.2
Base Voltage
115 vac (127 vac max)
cOndenser Fan mOtOr
Watts
rpm
amps
3.1
1100 CW Opposite
Shaft
0.03 Running
evapOratOr Fan mOtOr
1.7 each
9000
.02 each
2.75”
icOn
tm
unit dimensions
Model
Width
Height
Depth
Designer
23
13
/
16
inch
34-35 inches
26
3
/
4
inch
Professional
23
13
/
16
inch
34-35 inches
26
3
/
4
inch
nOte
Your Electrolux refrigerator drawers has been designed for built-
in installation. Your refrigerator drawers do not require additional
air space for top, sides or rear. The front grille must
nOt be
obstructed.
To ease unit installation and removal, it is recommended that the
cabinet rough opening dimensions be increased by at least ¼ inch
over the dimensions given for your unit.
impOrtant: pLease return this sheet tO it’s
OriGinaL LOcatiOn.
WarninG
double drawer refrigerator drawers are designed to be built-
in only. they can not be used for free-standing.
all screws supplied with the anti-tip Kit are for mounting
the bracket directly to wall studs. these screws will not work
if used with sheetrock (dry wall) or anything other than wall
studs.
2.75”
3.25”
icOn
tm
designer
icOn
tm
professional