background image

For all approved electric cooktop models, cut minimum
4" x 4" opening in right cabinet side panel and/or filler
panel, to route armoured cable to junction box

Oven cutout

28

1

/

4

" min.

28

7

/

8

" max.

4-1/2" maximum height allowed
from oven base to floor if cooktop
is installed directly over wall oven.
(5" maximum height allowed
with no cooktop.)

240 /208V
Junction box
for wall oven

Approx. 3"

24" min.

cutout depth

  *Critical dimension – MUST be applied
**For cooktop cutout dimensions refer to model-specific

product installation instructions on the web

240 /208V
Junction box
for electric
cooktop

Approx. 3"

36"

min.

Cooktop
 cutout**

To route armoured cable to junction box through left cabinet side panel
and/or filler panel, cut minimum 4" x 4" opening in wood base and runner

Side filler panels necessary to isolate oven from
adjoining cabinets. Panel height may need to
be modified to accommodate the depth of approved
electric cooktop models

   24" min.*

28

1

/

2

" min.

29" max.

Unit will overlap cutout (minimum) edges by 1"

Install 

3

/

4

" full plywood base on 2 runners, flush

with toe plate, capable of supporting 200 lbs.

Electric Cooktop Installation Over 

30" Single Electric Wall Oven

Electric Cooktop Installation Over 
30" Single Electric Wall Oven Specifications

Single Wall Ovens are approved to be used beneath Electrolux
ICON

electric cooktop models E36IC75FSS, E30IC75FSS,

E36EC70FSS and E30EC70FSS (electric cooktop models NOT
approved for use in this installation are E36EC75ESS,
E30EC65ESS and E36EC65ESS.

For detailed Electric Cooktop installation specifications, refer 
to product-specific section, pages 18-35.

Side filler panels necessary to isolate oven from adjoining
cabinets. Panel height may need to be modified to
accommodate the depth of approved electric cooktop models.

To route armoured cable to junction box, cut minimum 
4" x 4" opening in right cabinet side panel. 

Allow 4-1/2" maximum height from oven base to floor, 
if cooktop is installed directly over wall oven.

30" Single Electric Wall Oven Under-Counter 
Installation Specifications

Product Weights – 
(E30EW75EPS) 177 Lbs. / (E30EW75ESS) 168 Lbs.

Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 
60 Hertz AC only electrical supply with ground required on
separate circuit fused on both sides of line.

Connected Load (kW Rating) – 240 / 208 Volts = 4.0 / 3.0 kW

Amps @ 240 / 208 Volts = 16.6 / 14.4 Amps

Always consult local and /or national electric codes. 

Minimum 23-1/4" clearance for oven door depth when open.

Minimum 24" deep, cutout dimension is critical for proper install-
ation. If oven’s face profile does not fit flush against cabinet, or if
noise is heard from oven’s convection system, verify dimension.

Full oven base of solid plywood or similar material required,
capable of supporting 200 Lbs. Install over two runners and 
flush with toe plate. 

Base must be level and cabinet front must be square.

Side filler panels necessary to isolate oven from adjoining cabinets.

Allow 5" maximum height from oven base to floor, if NO cooktop
is installed directly over wall oven.

Note: Refer to Product Installation Guides for detailed instructions 

on the web at electroluxusa.com.

   

Summary of Contents for E30EW75EPS - Icon Professional Series

Page 1: ...411 Rev A English pages 1 6 Español páginas 7 13 Français pages 14 20 All dimensions are in inches cm Do not remove spacers on the side walls and or on the back of the built in oven These spacers center the oven in the space provided The oven must be centered to prevent excess heat buildup that may result in heat damage or fire PRODUCT DIMENSIONS CUTOUT DIMENSIONS AND CABINET WIDTH MODEL 30 76 2 c...

Page 2: ...3 wire or 4 wire single phase 120 240 or 120 208 Volt 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line time delay fuse or circuit breaker is recommended DO NOT fuse neutral The fuse size must not exceed the circuit rating of the appliance specified on the nameplate Consideration must be given for a combination built in oven and cooktop refer to unit...

Page 3: ... wires that extend out of the end of the supply cable of the appliance Connect the white wire from supply cable to the neutral white wire in the junction box Connect the black and red wires from the supply cable to the matching color wires in the junction box The bare wire must now be used to ground the appliance in accordance with local electrical codes Connect the bare copper ground wire to the ...

Page 4: ...ure 6 1 2 3 Figure 7 Mounting bracket installed in cabinet Oven Bracket Oven Right Side Tool supplied Mounting bracket released Cabinet Oven removed from the cabinet Hole where to insert the tool The wall oven can tip when the door is open The mounting brackets supplied with the wall oven must be attached to the cabinet and the appliance to prevent tipping of the wall oven and injury to persons Mo...

Page 5: ... box for built in oven Figure 8 TYPICAL UNDER COUNTER INSTALLATION OF AN ELECTRIC BUILT IN OVEN Approx 3 7 5 cm Cabinet side filler panels are necessary to isolate the unit from adjoining cabinets To reduce the risk of per sonal injury and tipping of the wall oven the wall oven must be secured to the cabinet s by mounting brackets Refer topage4formounting brackets installation 5 12 7 cm Max CUTOUT...

Page 6: ...n When the oven is set for a convection Convection element located at rear of the oven will turn on IMPORTANT NOTE A fan inside the oven will turn on as soon as the oven is operate Model and Serial Number Location The serial plate is located inside the oven on the side trim When ordering parts for or making inquires about your oven always be sure to include the model and serial numbers and a lot n...

Page 7: ...s cooktop models NOT approved for use in this installation are E36GC75ESS E46GC67ESS E36GC76EPS E48GC76EPS and E30GC64ESS For detailed Gas Cooktop installation specifications refer to product specific section pages 18 35 Side filler panels necessary to isolate oven from adjoining cabinets Panel height may need to be modified to accommodate the depth of approved gas cooktop models Minimum height op...

Page 8: ...6EC75ESS E30EC65ESS and E36EC65ESS For detailed Electric Cooktop installation specifications refer to product specific section pages 18 35 Side filler panels necessary to isolate oven from adjoining cabinets Panel height may need to be modified to accommodate the depth of approved electric cooktop models To route armoured cable to junction box cut minimum 4 x 4 opening in right cabinet side panel ...

Reviews: