background image

6

For Mobile Home Installations

The installation of this hood insert must conform to the 
Manufactured Home Construction Safety Standards, 
Title 24 CFR, Part 328 (formerly the Federal Standard 
for Mobile Home Construction and Safety, Title 24, 
HUD, Part 280) or when such standard is not appli-
cable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Commu-
nities and Setups) ANSI A225.1/NFPA 501A, or latest 
edition, or with local codes.

 Location Requirements

 

IMPORTANT: Observe all governing codes and ordi-
nances. Have a qualified technician install the hood 
insert. It is the installer’s responsibility to comply with 
installation clearances specified on the model/serial
rating plate. The model/serial rating plate is located 
behind the left filter on the rear wall of the hood
insert.
The range hood location should be away from strong 
draft areas, such as windows, doors and strong heat-
ing vents.
Grounded electrical outlet is required.
All openings in ceiling and wall where range hood will 
be installed must be sealed.
 

Location requirements

 

Product dimensions

12"

(30.5 cm)

2" 

(5.1 cm)

30" (76.2 cm)
36" (91.4 cm)

23" (58.4 cm)

10" 

(25.4 cm)

"

(1.0 cm)

2

(6.5 cm)

7½"

(19.0 cm)

29 " (74.0 cm)

35 " (89.2 cm) 

Serial Plate Location

 

Remove the grease filters.

 

The rating plate is located behind the filter by the  

  electrical box.

Summary of Contents for E30WV60PPS

Page 1: ... 91 4 cm Range Hood Guide d installation utilisation et d entretien 30 76 2 cm et 36 91 4 cm Hotte de la Cuisiniere Guia de Instalación Uso y Cuidado Campana de cocina de 30 76 2 cm y 36 91 4 cm E30WV60PPS E36WV60PPS 316902932 October 2013 LI314A ...

Page 2: ... toll free telephone support in the U S and Canada 1 877 4 ELECTROLUX 1 877 435 3287 For online support and Internet production information visit http www electroluxappliances com Table of contents 2013 Electrolux Home Products Inc All rights reserved Printed in Mexico NOTE Registering your product with Electrolux enhances our ability to serve you You can register online at www electroluxappliance...

Page 3: ...E READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING INSTALLATION MUST COMPLY WITH ALL LOCAL CODES IMPORTANT Save these Instructions for the Local Electrical Inspector s use INSTALLER Please leave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring this appliance ...

Page 4: ...l requirements specified To Reduce The Risk Of Fire Or Electric Shock Do Not Use This Hood Insert With Any External Solid State Speed Control Device TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high h...

Page 5: ...ll local codes and ordi nances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only...

Page 6: ...nician install the hood insert It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the hood insert The range hood location should be away from strong draft areas such as windows doors and strong heat ing vents Grounded electrical outlet is required ...

Page 7: ... greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific require ments in your area Venting Requirements Venting Methods Vent Exhaust Option The hood is designed for vertical or horizontal discharge Vertical discharge Use a 31 4 x 10 rectangular duct Horizontal discharge Use a 31 4 x 10 rectangular duct NOTE Flexible ven...

Page 8: ... damper flap NOTE The exhaust adaptor damper can be installed up to 1 inch on either side of the hood center to ac commodate offcenter ductwork In extreme offcenter installations one end of the duct connector may need to be trimmed to clear the electrical cable clamp Exhaust transition damper Pivot Top back edge Top back edge Exhaust transition damper Pivot Mark holes Select the vent option that y...

Page 9: ...all two horizontal supports at least 4 x 2 between two wall studs at the bottom and upper mounting holes installation location The horizontal support must be flush with the room side of the studs Use cleats behind both sides of the support to secure to wall studs Reinstall drywall and refinish IMPORTANT Framing must be capable of supporting 100 lbs Centerline of Installation Space View From Cleats...

Page 10: ...pports Replace filters Check operation of the hood If range hood does not operate Check that the circuit breaker is not tripped or the house fuse blown Disconnect power supply Check that wiring is correct Keep your Installation Instructions and Use and Care Guide close to range hood for easy reference Electrical connection Description of the Hood 1 2 3 4 5 6 1 Blower control switch 2 Light control...

Page 11: ...e maintenance or failure to observe the above safety recommendations Grease Filter To Remove Metal Grease Filters Use 2 hands to remove the metal grease filters Grasp filter handles push toward the rear of the range hood and pull down on the front handle to remove To Reinstall Metal Grease Filters Grasp filter handles and place rear of filter into rear track Push down on the rear handle and set th...

Page 12: ...persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN CLAIMS BASED ON IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR ...