8. INSTALLATION
WARNING!
Refer to Safety chapters.
8.1 Positioning
This appliance can be installed in a dry,
well ventilated indoor where the ambient
temperature corresponds to the climate
class indicated on the rating plate of the
appliance:
Climate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Some functional problems
might occur for some types
of models when operating
outside of that range. The
correct operation can only
be guaranteed within the
specified temperature range.
If you have any doubts
regarding where to install the
appliance, please turn to the
vendor, to our customer
service or to the nearest
Authorised Service Centre.
The plug should be
accessible after installation.
8.2 Electrical connection
• Before plugging in, ensure that the
voltage and frequency shown on the
rating plate correspond to your
domestic power supply.
• The appliance must be earthed. The
power supply cable plug is provided
with a contact for this purpose. If the
domestic power supply socket is not
earthed, connect the appliance to a
separate earth in compliance with
current regulations, consulting a
qualified electrician.
• The manufacturer declines all
responsibility if the above safety
precautions are not observed.
• This appliance complies with the
E.E.C. Directives.
8.3 Ventilation requirements
The airflow behind the appliance must be
sufficient.
1. Put the freezer in horizontal position
on a firm surface. The cabinet must
be on all four feet.
2. Make sure that the clearance
between the appliance and rear wall
is 5 cm.
3. Make sure that the clearance
between the appliance and the sides
is 5 cm.
9. TECHNICAL DATA
9.1 Technical data
Height
mm
876
Width
mm
1336
Depth
mm
667,5
Rising time
Hours
31
www.electrolux.com
12
Summary of Contents for EC4200AOW1
Page 54: ...www electrolux com 54 ...
Page 55: ...ITALIANO 55 ...