Alarm Codes
•
iD0 Code - family : Tacho Problem
•
iD0
code: no signal
•
The alarm is stored and displayed only in service mode; there is a new
control for each new phase.
•
If the washing pump is activated but there is no tacho signal for 30 sec
then the motor speed is set to full speed and the heating element is not
activated.
•
iD1
code: no signal
•
The alarm is stored and displayed only in service mode.
•
If the washing pump is activated but there is no tacho signal for 5 sec then
the heating element is temporarily deactivated. If after another 30 sec
there is still no signal the appliance displays an error code iD0.
•
iE0 – family: flow controller problem
•
iE0
code: flow control position (spray arm level)
•
The alarm is stored and displayed only in service mode; the flow controller
will try to recover for each new positioning request.
•
The alarm is signalled if the desired position of the flow controller is not
reached within a certain time:
o
If the flow controller is not moving at all or if the sensor is
broken or shorted, the timeout is 12 seconds.
o
If the flow controller is indeed moving but cannot find the
position, the overall timeout is up to about 110 seconds.
•
If the alarm is signalled, then heating element is deactivated as long as the
alarm is active.
•
iF0 Code - family : water level problem
•
iF0
Code : overfilling detected
•
The alarm is stored and displayed only in service mode; the program
continues.
•
The error situation is recognized when the total filling times exceed the
limits.
•
The times are accumulated at each subsequent filling and reset every time
the drain is activated.
•
If the alarm is detected, the heating element is not activated and the
subsequent fillings are ignored.
•
iF1
code: high water level
•
The alarm is stored and displayed only in service mode.
•
The alarm condition is recognized if the safety water level is exceeded for
more than 4 sec.
•
A drain phase is activated until the water level drops below the safety level.
•
The washing program continues only if this condition is achieved